beautypg.com

Ú installation instructions, Important safety information, Danger of death – Siemens LD97AA670 User Manual

Page 6: Risk of fire, Risk of injury, Risk of electric shock, Danger of suffocation, Risk of tipping, General information, Exhaust air mode

background image

en

Ú

Installation instructions

:

Important safety information

Read these instructions carefully. Only then will you be able to

operate your appliance safely and correctly. Retain the

instruction manual and installation instructions for future use or

for subsequent owners.
The appliance can only be used safely if it is correctly installed

according to the safety instructions. The installer is responsible

for ensuring that the appliance works perfectly at its installation

location.
The width of the extractor hood must correspond at least with

the width of the hob.
For the installation, observe the currently valid building

regulations and the regulations of the local electricity and gas

suppliers.
Danger of death!

Risk of poisoning from flue gases that are drawn back in.
Always ensure adequate fresh air in the room if the appliance is

being operated in exhaust air mode at the same time as room

air-dependent heat-producing appliance is being operated.

Room air-dependent heat-producing appliances (e.g. gas, oil,

wood or coal-operated heaters, continuous flow heaters or water

heaters) obtain combustion air from the room in which they are

installed and discharge the exhaust gases into the open air

through an exhaust gas system (e.g. a chimney).
In combination with an activated vapour extractor hood, room air

is extracted from the kitchen and neighbouring rooms - a partial

vacuum is produced if not enough fresh air is supplied. Toxic

gases from the chimney or the extraction shaft are sucked back

into the living space.

Adequate incoming air must therefore always be ensured.

An incoming/exhaust air wall box alone will not ensure

compliance with the limit.

Safe operation is possible only when the partial vacuum in the

place where the heat-producing appliance is installed does not

exceed 4 Pa (0.04 mbar). This can be achieved when the air

needed for combustion is able to enter through openings that

cannot be sealed, for example in doors, windows, incoming/

exhaust air wall boxes or by other technical means.

In any case, consult your responsible Master Chimney Sweep.

He is able to assess the house's entire ventilation setup and will

suggest the suitable ventilation measures to you.
Unrestricted operation is possible if the vapour extractor hood is

operated exclusively in the circulating-air mode.
Danger of death!

Risk of poisoning from flue gases that are drawn back in. If

installing a ventilation system in a room with a heat-producing

appliance connected to a chimney/flue, the electricity supply to

the hood must be equipped with a suitable safety switch.
Risk of fire!

Operating several gas burners at the same time gives rise to a

great deal of heat. The ventilation appliance may become

damaged or catch fire. The ventilation appliance must only be

combined with gas burners that do not exceed the maximum

total output of 12.4 kW.

Risk of fire!

Grease deposits in the grease filter may catch fire. The

specified safety distances must be observed in order to

prevent an accumulation of heat. Observe the specifications

for your cooking appliance. If gas and electric hobs are

operated together, the largest specified distance applies.
Only one side of the appliance may be installed directly next

to a high-sided unit or a wall. The distance between the

appliance and wall or high-sided unit must be at least 50 mm.

Risk of injury!

Components inside the appliance may have sharp edges.

Wear protective gloves.

Risk of injury!

The appliance is heavy. To move the appliance, 2 people are

required. Use only suitable tools and equipment.

Risk of electric shock!

Components inside the appliance may have sharp edges. These

may damage the connecting cable. Do not kink or pinch the

connecting cable during installation.
Danger of suffocation!

Packaging material is dangerous to children. Never allow

children to play with packaging material.
Risk of tipping!

The appliance is very narrow and can tip over easily. Do not set

the appliance on an uneven surface. Set the appliance flat on

the surface.

General information

Exhaust air mode
Note:
The exhaust air must not be conveyed into a functioning

smoke or exhaust gas flue or into a shaft which is used to

ventilate installation rooms which contain heat-producing

appliances.

Before conveying the exhaust air into a non-functioning smoke

or exhaust gas flue, obtain the consent of the heating

engineer responsible.

If the exhaust air is conveyed through the outer wall, a

telescopic wall box should be used.

Exhaust duct
Note:
The appliance manufacturer does not assume any

warranty for complaints attributable to the pipe section.

The appliance achieves its optimum performance by means of

a short, straight exhaust air pipe and as large a pipe diameter

as possible.

Because of long rough exhaust air pipes, many of which are

pipe bends or have diameters smaller than 150 mm, the

optimum extraction performance is not achieved and fan

noise is increased.

The pipes or hoses for laying the exhaust duct must consist of

non-combustible material.

Round pipes

An inner diameter of 150 mm, but at least 120 mm, is

recommended.
Flat ducts

The inner cross-section must correspond to the diameter of the

round pipes.
Ø 150 mm approx. 177 cm

2

Ø 120 mm approx. 113 cm

2

Flat ducts should have no sharp deflections.

Use sealing strip for deviating pipe diameters.

Gas hob

The appliance can be used in conjunction with a gas hob.
Caution!

The gas hob must not exceed the following values:

Total maximum output: 12.4 kW

Maximum output for a single burner: 5 kW

Maximum of 5 single burners

Electrical connection
:

Risk of electric shock!

Components inside the appliance may have sharp edges. These

may damage the connecting cable. Do not kink or pinch the

connecting cable during installation.
Check the indoor installation before connecting the appliance.

Ensure that the indoor installation is sufficiently fused. The

voltage and frequency of the appliance must correspond to that

of the electrical installation (see rating plate).
The appliance corresponds to protection class I and must only

be operated with a protective earth connection.
An all-pole isolating switch with at least a 3 mm contact gap

must be fitted in the installation. The plug must still be

accessible after installation.
Only a qualified electrician who takes the appropriate

regulations into account may install or replace the connecting

cable.