K. preoperational instructions non-coin models, L. compressed air requirements, Compressed air supply air pressure – ADC AD-170SE User Manual
Page 40
36
K. PREOPERATIONAL INSTRUCTIONS
NON-COIN MODELS
1. To start the dryer:
a. Microprocessor Controller (Computer) Dryers...
1) The light emitting diode (L.E.D.) display will read “READY.”
2) Press the “E” on the keypad.
3) The dryer will start, and the L.E.D. display will show “MANUAL DRYING CYCLE E, DRYING
TEMPERATURE 180º F, DRYING TIME 50 MINUTES.”
b. Dual Timer Dryers...
1) Turn drying timer knob for a time of 20 minutes.
2) Select “High Temp.”
3) Push “Push To Start” button.
4) To stop dryer, open the main door.
2. Spin and dwell (stop) times are adjustable at the reversing timer.
L. COMPRESSED AIR REQUIREMENTS
The dryer requires an external supply of compressed air (2.5 cfh [cubic feet per hour] @ 80 psi [0.07 cmh [cubic
meters per hour] @ 5.51 bar] for gas models and 3.25 cfh @ 80 psi [0.09 cmh @ 5.51 bar] for steam models).
For steam models, compressed air is necessary for the air operated steam damper. On both the steam models
as well as the gas models, compressed air is necessary/required for blower air jet operation...to clean lint from
the impellor/fan (squirrel cage).
1. Air Requirements
a. Microprocessor Controller (Computer) Dryers
Shaded areas are stated in metric equivalents
Compressed Air Supply
Air Pressure
Normal
80 psi
5.51 bar
Minimum Supply
70 psi
4.82 bar
Maximum Supply
90 psi
6.21 bar