22
Important information
Installation Instructions:
ṇ
The installation of the extractor hood
above gas cooking devices, at a
minimum height of 650 mm – Fig. 1 – is
permitted provided that the following
nominal heat loads (Hs) are not exceeded:
❑ Gas cookers
Load of one hotplate
max.
0
3.0 kW
Load of all hotplates max.
0
8.3 kW
Load of the oven max.
0
3.9 kW
❑ Gas hobs
Load of one hotplate
max.
0
3.9 kW
Load of all hotplates max. 11.3 kW
❑ Gas ceramic hotplate
The nominal heat load specifications do
not apply to closed gas ceramic hobs.
Always observe the specifications of the
hob manufacturer.
❑ Solid-fuel cookers
The maximum nominal heat loads and
the minimum distance are the same as
for gas cookers.
ṇ
The extractor hood must not be
installed over a solid fuel cooker – a
potential fire hazard (e.g. flying sparks) –
unless the cooker features a closed,
non-removable cover and all national
regulations are observed.
ṇ
The smaller the gap between the
extractor hood and hotplates, the greater
the likelihood that droplets will form on the
underside of the extractor hood.
ṇ
Old appliances are not worthless
rubbish. Valuable raw materials can be
reclaimed by recycling old appliances.
Before disposing of your old appliance,
render it unusable.
ṇ
You received your new appliance in a
protective shipping carton. All packaging
materials are environmentally friendly and
recyclable. Please contribute to a better
environment by disposing of packaging
materials in an environmentally-friendly
manner.
Please ask your dealer or inquire at your
local authority about current means of
disposal.
ṇ
The extractor hood can be used in
exhaust air or circulating air mode.
ṇ
Always mount the extractor hood over
the centre of the hob.
ṇ
Minimum distance between electric
hob and bottom edge of extractor hood:
430 mm, Fig. 1.
Additional information concerning gas
cookers:
ṇ
When installing gas hotplates, comply
with the relevant national statutory
regulations (e.g. in Germany: Technische
Regeln Gasinstallation TRGI).
ṇ
Always comply with the currently valid
regulations and installation instructions
supplied by the gas appliance
manufacturer.
ṇ
Only one side of the extractor hood
may be installed next to a high-sided unit
or high wall. Gap at least 300 mm.