Technical data, For the customer – Siemens DH04101 User Manual
Page 16
16
Technical data
Model
DH 04101 DH 05101 DH 06101 DH 06111
Model
Pressurised (closed) / depressurised (open)
Weight
Kg
1.4
1.8
1.8
1.8
Dimensions
mm
250 x 144 x 100
Operating mode
Continuous
Mains connection
Mains plug
Permanent electrical connection
Nominal voltage
220 Ć 240 V
Nominal power
kW / 230 V
3.5
4.6
6
6
Class of protection in accordance with
IEC 335Ć1
I
I
I
i
Class of protection in accordance with
IEC 529
IP 24 (splashĆproof)
Fuse protection
A
16
20
32
32
Frequency
50
50
50
50
Fittings connection
Inches
3/8
3/8
3/8
1/2
Minimum flow pressure
0.1 M Pa (1 bar)
Maximum flow pressure
1 M Pa (10 bar)
Water volume at switchĆon
approx.
l/min
1.3
1.8
2.3
2.3
Water volume at switchĆoff
approx.
l/min
1
1.4
1.8
1.8
Typical warm water output
at 37 ºC
l/min
1.8
2.5
3.0
3.0
After installation, give the user the operating instructions and explain how the appliance
works.
For the customer
Operation
FlowĆthrough water heaters in this product series work automatically.
S
To switch on: Open the tap fully. The flowĆthrough water heater switches on and the
ON indicator (only on the DH06111) lights up. The water is heated as it flows through the
appliance.
S
To switch off: Close the tap, the appliance switches off.
S
To regulate the water temperature: Open the tap fully, the appliance switches on. Now
increase the temperature by reducing the water flow volume.