beautypg.com

Siemens DH04101 User Manual

Page 12

background image

12

Product description

This instruction manual describes various appliance models.
General

S

The hydraulically controlled flowĆthrough water heater is suitable for either an open
(depressurised) or closed (pressurised) connection.

S

The flowĆthrough water heater continuously heats water while it flows through the appliance.

S

The appliance must not be operated with preheated water, otherwise the overtemperature
protection will be triggered.

DH04101

S

This appliance is connected to the mains by a plug.

DH05101, DH06101 and DH06111

S

These appliances are designed for permanent electrical connection.

DH06111

high level appliance

DH04101, DH05101 and DH06101

under counter appliances

For the qualified engineer

Preparation for installation

For all appliances

S

There must be a clearance of approximately 60 mm on all sides of the appliance for installation.

S

Observe the technical data for the appliance

S

Flush the coldĆwater supply line and shut it off.

Only for DH05101, DH06101 and DH06111 (permanent electrical connection)

S

Unscrew the screws on the housing cover and remove the lid.

Wall mounting

For all appliances

S

Secure the appliance using the installation template, screws and wall plugs so that it is vertical
and flush against the wall.
1. Locate the appliance on the screw and press down.

2. Screw in the second screw through the mounting tab and tighten.

Only for DH05101, DH06101 and DH06111 (permanent electrical connection)

S

For an exposed electrical connection, the different methods of routing the supply line found on
the assembly template must be observed.

S

The cable bushing must firmly enclose the connecting cable to ensure that it is protected
against moisture. In the event of damage, seal the opening so that it is watertight.

This manual is related to the following products: