After installation

DE05101, DE06101, DE06111, DE08101
and DE08111 (fixed electrical connection)

Switch on the fuses.

DE04101 and DE10104

Insert the plug into the mains socket.

First start-up

Initial rinsing

Open the warm water tap and allow water to

flow for at least 1 minute (flow-rate at least
2 litres per minute). Only then (for safety rea-
sons) will the appliance begin to heat.
Info: The appliance will not heat if the dispensed
water flow is interrupted prematurely. Open the
warm water tap again and allow water to flow
for at least 1 minute.

Tip: Should the appliance not start because of a
reduced flow-rate, remove the perlator, aerator or
similar before starting and repeating the process.

Important: If the continuous-flow heater does not
have sufficient water flow due to low water line
pressure in your domestic plumbing system:

Switch off the circuit-breakers/fuses or remove

the mains plug.
Remove the flow-rate limiter (

H1 – H4).

Controlling temperature

The supply temperature (probably lower in winter)
and pressure fluctuations can influence the tem-
perature of the water leaving the tap (refer to figure
on page 22).

Turn the valve slowly in the closed direction for

higher temperatures (

F1).

Add cold water for lower temperatures (

F2).

Hand over the installation and operating instruc-

tions to the user and explain how the appliance
operates.