beautypg.com

Programmable vfo – Kenwood TM-281A User Manual

Page 68

background image

61

11

6 Press

[MENU] to complete the setting and store the

Power-on message.

7 Press any key other than [MENU] to exit Menu Mode.

Note: If a Power-on message is not set, the transceiver model name
appears when the transceiver power is turned ON.

PROGRAMMABLE VFO

To limit the operating frequencies within a certain range,
program the upper and lower frequency limits to the
program VFO parameters. For example, if you select 144
MHz for the lower limit and 145 MHz for the upper limit,
the tunable range will be limited from 144.000 MHz to
145.9975 MHz.

1 While in VFO mode, press [F], [MENU] and turn the

Tuning control to select Menu No. 7 (P.VFO).

• The current programmable frequency range for the band

appears.

2 Press

[MENU] and turn the Tuning control to select

the lower limit frequency (in MHz).

3 Press

[MENU] and turn the Tuning control to select

the upper limit frequency (in MHz).

4 Press

[MENU] to store the setting or any other key to

cancel.

5 Press any key other than [MENU] to exit Menu Mode.

Note:

You cannot program the 100 kHz or lower digits.

The upper limit frequency cannot be set lower than the selected

lower limit frequency.