Maintenance, Kdar company 9, Maintenance schedule—engine – Hot Max Torches PW2000 User Manual

Page 10: Engine oil change, Air cleaner service, Spark arrestor cleaning

background image

KDAR Company

9

Item

What To Do

Each

Use

First

Month or
20 Hours

Every 3

Months or

50 Hours

Every 6

Months or
100 Hours

Every Year

or 300
Hours

Engine Oil

Check Oil Level

X

Change

X

X

Air Cleaner

Check

X

Clean or Replace

X

Sedimant Cap

Clean

X

Spark Plug

Check, adjust gap and clean

X

Spark Arrester

Clean

X

Valve Clearance

Check & Adjust

X

Fuel Tank and Strainer

Clean

X

Fuel Filter (Attached to fuel
valve)

Clean - Replace if necessary

X

Fuel Line

Clean - Replace if necessary

X

Exhaust System

Check for leakage. Tighten
or replace gasket, if neces-
sary

X

Fittings & Fasteners

Check, replace if necessary

X

Maintenance Schedule—Engine

Maintenance

Engine Oil Change

1. Change oil while engine is warm to assure

complete and rapid draining.

2. Power washer should be on a level surface.
3. Remove oil filler cap.
4. Place pan under generator to catch oil.
5. Remove oil drain plug.
6. Allow oil to drain completely.
7. Replace drain plug.
8. Refill with recommended oil (page 5).
9. Check oil level.

Oil Filler

Cap

Oil Drain

Plug

Air Cleaner Service

1. Unsnap the air cleaner cover clips.
2. Remove the air filter element.
3. Wash the element in a solution of household

detergent and warm water and rinse thoroughly
(a nonflammable or high flash point solvent
can also be used).

4. Allow to dry completely.
5. Pour a small amount of clean en-

gine oil on the element and
squeeze out the excess.

6. Reinstall air filter element and

replace cover.

1. Unsnap the air cleaner cover clips.
2. Remove the air filter element.

Spark Arrestor Cleaning

Note: Muffler must be cool to touch.
1. To remove the Spark Arrestor, loosen screw on

clamp and remove the Arrestor. (Make sure to
handle carefully and gently)

2. Lightly brush the element in a solution of

household detergent and warm water and rinse
thoroughly (a nonflammable or high flash
point solvent can also be used).

3. Re-install Arrestor and tighten Clamp.