beautypg.com

Hot Max Torches MM-1 User Manual

Page 5

background image

KDAR Company

4

Installation & Setup

Oxygen & Acetylene Filling


The Mobile Max is shipped with the tanks empty. Therefore, you will have to take the tanks to a local welding
gas supply distributor to have them filled prior to welding. Different welding gas suppliers handle tank filling
differently; some will fill the tanks while you wait while others require a tank exchange. You will need to se-
lect the type of supplier you prefer.

Attaching Regulators and Hoses


1. Secure the Mobile Max to an immovable object

such as a pole or a cart specifically designed to
hold the torch kit.

Note: Although the Mobile Max is intended to
be portable; it is important that the unit be secured
so it will not tip over during setup and operation.


2. Briefly open the oxygen tank valve (1) to remove

any debris that may have accumulated.


3. Wipe the oxygen regulator fitting (2) with a clean

dry cloth and tread the fitting onto the tank valve
and tighten with a wrench. Thread in the regulator
valve lever (3).


4. Using the acetylene tank valve key; briefly open

the acetylene tank valve (4) to remove any debris
that may have accumulated.


5. Wipe the acetylene regulator fitting (5) with a

clean dry cloth and thread the fitting onto the tank
valve and tighten with a wrench. Thread in the reg-
ulator valve lever (3).


6. Using compressed air; blow out the hoses prior to

using them for the first time.


7. Attach the hoses to the regulators; green to the ox-

ygen and red to the acetylene and tighten with a
wrench.


8. Attach the other end of the hose to the appropriate

fittings on the torch handle and tighten with a
wrench.


Note: The acetylene hose has left hand (reverse)
treads and is marked with notches in the fitting (6).

1

2

Oxygen

Regulator

Oxygen Tank

Valve

Acetylene

Regulator

Acetylene Tank

Valve

Acetylene Tank

Valve Key

4

5

Hose Fittings

6

3

3