T R O U B L E S H O O T I N G C H E C K L I S T

TROUBLE

POSSIBLE CAUSE

REMEDY

Unit does not operate.

Insufficient electric power unit.

Check power source.

Defective plug or cord.

Check and repair if necessary.

Power switch defective.

Replace.

Cooking temperature not correct.

Cook thermostat out of calibration.

Calibrate.

Holding temperature not correct.

Hold thermostat out of calibration.

Calibrate.

Timer runs down, but oven will not Timer not de-energizing cook circuit. Replace timer.

go into HOLD.

Cook thermostat erratic — will not

Cook thermostat.

Replace thermostat.

hold calibration.

Hold thermostat erratic — will not

Hold thermostat.

Replace thermostat.

hold calibration.

Oven goes from cooking

Hold thermostat.

Replace hold thermostat.

temperature to cold.

Oven will not go into cook cycle

Timer or contactor.

With timer turned ON, line

when timer and cook thermostat

voltage should appear across

are ON.

terminal 2 and 3 of timer. If not,

replace timer.

If line voltage does appear across

terminal 2 and 3 of timer, it should

also appear across holding coil

of contactor.

If line voltage does appear across

holding coil, and it won’t close its

contacts, replace contactor.

It takes too long to cook.

Heating element open, resulting in

Replace element.

(Temperature O.K.)

low wattage.

Cannot control temperature but

Heating element grounded.

Replace element.

thermostats check O.K.

S E R V I C E

D A N G E R

DISCONNECT UNIT FROM

POWER SOURCE BEFORE

CLEANING OR SERVICING.

This manual is related to the following products: