beautypg.com

Alto-Shaam 1000-TH-II User Manual

Page 12

background image

TH-II

INSTALLATION

/

OPERATION

/

SERVICE MANUAL

PG

. 11

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National Electrical

Code and applicable local codes.

Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is easily

accessible in case of an emergency. Arcing will occur

when connecting or disconnecting the unit unless all

controls are in the “

OFF

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed by a

licensed electrician in accordance with applicable

local electrical codes.

750- and 1000-TH-II models at 208-240V are dual

rated units with a conversion switch mounted under

an access cover on the rear of the oven, near the

power cord.

With the voltage conversion switch in the 200-208V

(UPPER) position, the oven will function properly

with a source voltage of between 200 and 208.

With the voltage conversion switch in the 220-240V

(LOWER) position, the unit will function properly

with a source voltage of between 220 and 240.
NOTE:

ALL 208-240V units are shipped from the

factory with the voltage conversion switch

in the 220-240 position.

All 125V rated units will function properly with a

source voltage of between 100 and 125, 60 Hz.

The 125V rated units are provided with a cord and plug

[NEMA #5-20P]. Have a licensed electrician install the

proper outlet configuration as required for the unit in

accordance with applicable, local electrical codes. This

will assure a safe and trouble-free installation.

230V:

To prevent an electrical shock hazard between

the appliance and other appliances or metal parts

in close vicinity, an equalization-bonding stud is

provided. An equalization bonding lead must be

connected to this stud and the other appliances /

metal parts to provide sufficient protection against

potential difference. The terminal is marked with

the following symbol.

NOTE:

230V appliances must be connected to

an electrical circuit that is protected by

an external GFCI outlet.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

E L E C T R I C A L - 5 0 0 - T H - I I

VOLTAGE

PHASE

CYCLE

/

HZ AMPS

kW

CORD

&

PLUG

120

1

60

16

1.92

NEMA

5-20

P

20A - 125V

PLUG

208-240

(

AGCY

)

1

60

12.5

3.0

NO CORD

at 208

1

60

10.6

2.2

&

PLUG

at 240

1

60

12.2

2.93

230

1

50

12

2.75

CEE

7/7

220-230V

PLUG

E L E C T R I C A L - 7 5 0 - T H - I I

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

CORD

&

PLUG

120

1

60

14.2

1.7

NEMA

5-20

P

20A - 125V

PLUG

208-240

(

AGCY

)

1

60

14.4

3.0

NO CORD

at 208

1

60

14.6

3.0

&

PLUG

at 240

1

60

11.2

2.7

230

1

50

10.4

2.4

CEE

7/7

220-230V

PLUG

E L E C T R I C A L - 1 0 0 0 - T H - I I , - I I - S P L I T

(

EACH COMPARTMENT

)

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

CORD

&

PLUG

120

1

60

16.0

1.92

NEMA

5-20

P

20A - 125V

PLUG

208-240

(

AGCY

)

1

60

14.4

3.0

NO CORD

at 208

1

60

14.4

3.0

&

PLUG

at 240

1

60

11.1

2.7

230

1

50

10.4

2.4

CEE

7/7

220-230V

PLUG

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST BE
EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.

ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

Ensure that the voltage conversion switch position

and the available power source match.

This manual is related to the following products: