Had product manual, Had part number index, H a d – High Country Tek HAD Series User Manual
Page 8

HAD Product Manual
________________________________________________________________________________
High Country Tek, Inc.
208 Gold Flat Court
Nevada City, CA, 95959.
Tel: (1) 530 265-3236
021-00141 Rev B2.1
8/8
HAD Part Number Index
Consult factory for custom options
ANALOG PROPORTIONAL VALVE DRIVER SERIES
CONNECTOR
H A D
POT
DITHER FREQUENCY ( 050, 100, 130 ETC.)
DITHER
RAM
P
CURRENT
CURRENT: Select the current range
that includes the m
axim
um
desired
current.
W
= 31m
A to 63m
A
X = 64m
A to 125m
A
Y = 126m
A to 250m
A
Z = 251m
A to 500m
A
E = 0.51A to 1.00A
K = 1.01A to 1.67A
G = 1.68A to 3.00A
M
= 3.34A to 5.00A
RAM
P: Select the num
ber of ram
p
controls. The ram
ps pot/s are preset
to 0 seconds; no adjustm
ents are
required if ram
ps are not desired.
S = Single ram
p pot for all ram
ps.
C = Individual ram
p pot per coil.
T = Individual ram
p pot per direction.
R = Individual ram
p pot per
direction of coil m
ovem
ent.
POT: Select the type of external potentiom
eter
desired for the valve driver.
No Letter = Standard option a non waterproof pot
and knob will be provided. Leave this
box blank.
V = Select the waterproof pot option. This option
includes a num
bered bezel and a knob.
CONNECTOR: Select the m
ethod
of connection desired.
No Letter = Term
inal block, standard
option.
Q = W
eatherPak Connector Option;
A six-pin tower and a four-pin
shroud; on six inch leads will be
provided.
DITHER: Select the frequency to
dither the valve. xxx if frequency in
Hertz. Please use three digits using a
leading 0 if required.
N = No Dither added.
Fxxx = Apply dither frequency
of xxx Hertz.
HAD******
D0000x
www.highcountrytek.com
CROSS OVER
MIN A
MIN B
B LIGHT
MAX
RAMP UP A
RAMP DOWN A
RAMP DOWN B
RAMP UP B
DITHER AMP
EXAM
PLE PART NUM
BER
HADGSF120
3 AM
P Dual Coil Valve Driver
with 1 Ram
p Pot and 120 Hz
Dither with Adjustable Am
plitidude
Figure, 4