OWNER'S MANUAL

CP700 COMMERCIAL
POWER AMPLIFIER

4

FRONT PANEL DESCRIPTION

Figure 1

1. Power Switch
This rocker switch supplies power to the CP700 amplifi er. A red LED located above the power switch
will illuminate when the CP700 is switched on.

2. Protect LED Indicators
The CP700 features several types of protection circuitry to prevent damage during turn-on or fault

conditions. If any of these LEDs illuminate, one of the various protection features is safeguarding the
amplifi er. The output relays will disconnect the speaker loads when the protection circuitry detects a

fault

condition.

Loudspeaker Protection

- When power is fi rst applied, the speaker protection relay is

open, preventing transients from reaching the loudspeakers. After the internal power supplies

have stabilized, the relay will close, connecting the amplifi er output to the load. The yellow

Protect LEDs will illuminate during this power up process.

Thermal Protection - The CP700 protection circuitry monitors itself for excessive internal

operating temperatures. In the event of this circuitry detecting abnormal thermal conditions

(blocked cooling fan and high ambient temperatures), the speaker relay will disconnect the

speaker load from the amplifi er. Once the internal operating temperature drops back to a safe

level, the relay will close, reconnecting the speaker load to the amplifi er.

Short Circuit Protection - The yellow Protect LEDs will illuminate should the amplifi er detect

a short circuit on the attached speaker load or if the load impedance is too low. When this

condition is detected, the internal speaker relays will open up, disconnecting the load from

the amplifi er. The protection circuitry will stay activated until the fault is cleared.

Note: Once the specifi c fault has been corrected, the power may have to be cycled to reset the

protection

circuitry.

3. Signal "Status" LED Indicator
The green "Status" LEDs will illuminate once the input signal has reached -26dBv or higher.

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

POWER

LIMIT

SIGNAL

CH-2

CP700

Commercial Power Amplifier

2

3

4

1