8.0 Troubleshooting

In the event of malfunction or faulty operating performance check that the installation and
adjustment work has been carried out and completed in accordance with these Operating
Instructions.

If malfunctions cannot be eliminated with the help of the following table
9.0 troubleshooting table”, the supplier or manufacturer should be consulted.

9.0 Troubleshooting table

-

ATTENTION !
It is essential that the safety regulations are observed when identifying faults.

ATTENTION !
- refer to item 10.0 and 11.0 prio
r to dismantling and repair work!
- refer to item 6.0 befo
re restarting the plant !

Fault

Possible cause

Corrective measures

No flow

Installed in wrong flow direction

Fit valve in direction of flow arrow.
Note installation position; refer to item
5.5.1!

Flange covers not removed

Remove flange covers

Ball float (Pos. 24.16) defective

Check lifting force; refer to item 7.1

Little flow

Wrong installation position

Note installation position;
refer to item 5.5.1
Correct installation position;
refer to item 7.2

Strainer clogged (Pos. 2)

Clean strainer; refer to item 7.1

Piping system clogged

Check piping system

Wrong controller size choosen

Correct selection acc. to flow diagram

Changed upstream pressure or back
pressure operating conditions

Correct selection acc. to flow diagram

Excessive amount of inert gases in sys-
tem

Use pressure compensation line and
external vent option; refer to item 7.4

No closure or internal
leakage

Controller clogged

Clean strainer and controller;
refer to item 7.1

Controller worn out

Change controller; refer to item 7.1

Controller incorrectly screwed into body Check seal face between body and con-

troller, tighten controller correctly; refer
to item 7.5

Controller operated above safe operating
pressure

Observe operating limits as per data
sheet, i.e. possibly select different con-
troller

External leakage

Hood (Pos. 16) not properly tightened
with hex. nut (Pos. 28) or cheese-head
screw (Pos. 27)

Tighten; refer to item 7.5

Flat gasket (Pos. 17) defective

Replace sealing;
refer to item 7.1