4.4 Technical data

for
- Principal dimensions
- Pressure-temperature-ratings, etc. refer to datasheet.

4.5 Marking

5.0 Installation

5.1 General notes on installation

The following items should be taken into account besides the general principles governing
installation work:

- Planners / construction companies or operators are responsible for positioning and

installing products.

- The valves are designed for application, not influenced from weather.
- For application outside or in adverse environments like corrosion-promoting conditions

(sea water, chemical vapours, etc.), special constructions or protective measures are
recommended.

Fig. 5
Address of manufacturer: refer to item 11.0 Warranty / Guarantee

ATTENTION !
- Remove flange covers if present.
- The interior of valve and pipeline must be free from foreign particles.
- Note installation position with reference to flow, see mark on valve.
- Steam line systems should be designed to prevent water accumulation.
- Lay pipelines so that damaging transverse, bending and torsional forces are

avoided.

- Protect valves from dirt during construction work.
- Connection flanges must mate exactly.
- Connecting bolts for pipe flanges should be mounted preferably from the

counter flange side (hexagon nuts from the valve side).

- Valve mountings such as actuators, handwheels, hoods must not be used to

take external forces, e.g. they are not designed for use as climbing aids, or as
connecting points for lifting gear.

- Suitable materials handling and lifting equipment should be used.

Refer to data sheet for weights.

- Keep the thread and shaft of the stem free from paint.
- Centre gaskets between the flanges.
- Strainers or filters should be installed before the valves.

CE-marking

Serial-No.

Year of manufacture clear speech

Notified body

Manufacturer

Nominal pressure

Nominal diameter

Type-Number

(1. and 2. position)

Stem sealing

Material of

internal parts

Kvs-value

Flow

Plug

design

characteristic

Customer-specific

information

This manual is related to the following products: