6) REPAIR PARTS
BEFORE ATTEMPTING ANY REPAIRS TO THE HEATER, MAKE SURE THAT THE 
ELECTRICAL BREAKER IS “OFF” AND CONFIRM THAT THERE IS NO VOLTAGE AT 
THE HEATER.
*
Heating element assembly consists of one heater core and wire element(s) complete.
** Flow meter kit consists of paddle wheel, dowel pin, O ring and 4 mounting screws.
Transformer
Control
Board
Fuse
Flow Meter Kit **
Hall Effect Board
(behind Flow Meter)
Triac
Heating
Element
Assembly *
Optical
Sensor
Board
Emergency
Cut Off
Contactor
9
13) The display can be turned off or on. Press and hold 
the DOWN and RIGHT buttons for 3 seconds. If the 
display is off, it can be turned on by pressing and 
holding the same DOWN and RIGHT buttons for 3 
seconds.
+
[
+
+
]
=
Service and repairs are to be performed by licensed 
electricians or qualified servicemen. 
01/14
9326/9327
Page 11 of 12