12) FAULTS are communicated through the LCD display.
The display will switch from the SETPOINT screen to the
FAULT screen and back again every 3 seconds. FAULTS
indicate an undesirable condition and will immediately
shut down the operation of the heater. If faults are
appearing on your heater call Eemax Technical Support
for assistance.

ERROR CODES:

E0: Excessive water flow detected

Corrective action: Using the OUTLET BALL VALVE, slowly reduce water flow until

the desired temperature is achieved. The temperature is proportional to the flow through the
heater; the lower the flow, the higher the temperature and vice versa.

Keep the INLET BALL VALVE fully “OPEN”. NEVER RESTRICT THE WATER
FLOW USING THE INLET VALVE.

E1: Inlet temperature too hot to generate heat

FAULT CODES:

F0: Thermistor out of range

F1: No change in water temperature detected

F2: Leak detected

13) The security of the heater settings is provided by
pressing and holding the LEFT and UP buttons for 3
seconds to lock the buttons. Once locked, the buttons
have no function. Press and hold the same LEFT and UP
buttons for 3 seconds to unlock the buttons.

The security status can be checked at any time by
pressing any one button. If the system is locked, the
screen will display “BUTTONS LOCKED”.

[ + ] =

8

01/14

9326/9327

Page 10 of 12