12) FAULTS are communicated through the LCD display. 
The display will switch from the SETPOINT screen to the 
FAULT screen and back again every 3 seconds. FAULTS 
indicate an undesirable condition and will immediately 
shut down the operation of the heater. If faults are 
appearing on your heater call Eemax Technical Support 
for assistance. 
ERROR CODES:
E0: Excessive water flow detected
Corrective action: Using the OUTLET BALL VALVE, slowly reduce water flow until
the desired temperature is achieved. The temperature is proportional to the flow through the 
heater; the lower the flow, the higher the temperature and vice versa.
Keep the INLET BALL VALVE fully “OPEN”. NEVER RESTRICT THE WATER 
FLOW USING THE INLET VALVE. 
E1: Inlet temperature too hot to generate heat
FAULT CODES:
F0: Thermistor out of range
F1: No change in water temperature detected
F2: Leak detected
13) The security of the heater settings is provided by 
pressing and holding the LEFT and UP buttons for 3 
seconds to lock the buttons. Once locked, the buttons 
have no function. Press and hold the same LEFT and UP 
buttons for 3 seconds to unlock the buttons.
The security status can be checked at any time by 
pressing any one button. If the system is locked, the 
screen will display “BUTTONS LOCKED”. 
[ + ] =