General

Refer to the Features and Components section of this manual (page

7) for the location of components mentioned in the instructions

that follow.
NEVER turn on power to the water heater without being certain the

water heater is filled with water and a temperature and pressure

relief valve is installed in the relief valve opening.
DO NOT TEST ELECTRICAL SYSTEM BEFORE HEATER IS

FILLED WITH WATER. FOLLOW FILLING AND START-UP

INSTRUCTIONS IN OPERATION SECTION.

fIllInG the water heater

1. Turn off the electrical disconnect switch.
2. Close the water heater drain valve.
3. Open a nearby hot water faucet to permit the air in the system

to escape.

4. Fully open the cold water inlet pipe valve allowing the heater and

piping to be filled.

5. Close the hot water faucet as water starts to flow. The

heater is now ready for STARTUP and TEMPERATURE

REGULATION.

InItIal start up

The following checks should be made by the installer when the heater

is placed into operation for the first time.
1. Turn off the electrical disconnect switch.
2. Open the front panel or top access cover, check all water and

electrical connections for tightness. Also check connections on top

and or sides of heater. Repair water leaks and tighten electrical

connections as necessary.

3. Depress the red manual reset button on each Thermostat/ECO

combination control. (See Figure 5, Figure 6, Figure 7 or Figure 8)

4. Turn on the electrical disconnect switch.
5. Observe the operation of the electrical components during the first

heating cycle. Use care as the electrical circuits are energized.

6. Close the front panel or top access cover.
Temperature control and contactor operation should be checked by

allowing heater to come up to temperature and shut off automatically.

Use care as the electrical circuits are energized.

draInInG the water heater

The water heater must be drained if it is to be shut down and exposed

to freezing temperatures. Maintenance and service procedures may

also require draining the heater.
1. Turn off the electrical disconnect switch.
2. Open a hot water valve until the water is cool, then close the

supply water inlet valve to heater.

3. Attach hose to outlet opening of drain valve and direct end to drain.
4. Open a nearby hot water faucet and the heater drain valve.
5. If the heater is being drained for an extended shutdown, it is

suggested the drain valve be left open during this period. The

hose may be removed.

Follow FILLING instructions when restoring hot water service.