beautypg.com

Troubleshooting chart – State SPX 50 DHPT User Manual

Page 18

background image

18

TROUBLESHOOTING CHART

PROBLEM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

NO HOT WATER

1. No power to the water heater (No

lights on the unit are on).

2. Unit in Vacation mode

3. High temperature limit switch open

4. Hot water usage pattern exceeds the

capability of the water heater in

current mode

5. Non-functioning upper temperature

sensor

1. Check for blown fuse or tripped breaker.

Restore power to unit.

2. Press Mode/Enter button and return to desired

operating mode.

3. Reset the high temperature limit switch; see

“Safety shut-off” section for more information.

4. Change to different mode or modify usage pat-

terns.

5. Contact a qualified person for service.

INSUFFICIENT HOT WATER/
SLOW HOT WATER
RECOVERY

1. Temperature set-point too low

2. Air filter dirty

3. Hot water usage pattern exceeds the

capability of the water heater in

current mode

4. Water connections to unit reversed

5. Heat lost through long run of exposed

pipe

6. Hot water leak at faucet or piping

7. Non-functioning heating element

8. Sediment or scale build up in tank

1. Increase set point temperature; see “Adjusting

the User Interface Module” section

2. Clean air filter

3. Change to different mode or modify usage

patterns (For example if in Efficiency Mode

switch to Hybrid Mode)

4. Ensure the cold connection is at the bottom

and that the hot connection is at the top

5. Insulate exposed piping

6. Repair hot water leaks

7. Call qualified person for service

8. Drain and flush tank. Water conditioning may

be necessary to minimize build up

HIGH OPERATION COSTS

1. Temperature set-point too high

2. Air filter dirty

3. Electric mode selected

4. Water connections to unit reversed

5. Heat lost thru long run of exposed

pipe

6. Hot water leak at faucet or piping

7. Sediment or scale build up in tank

1. Decrease set point temperature; see “Adjusting

the User Interface Module”

2. Clean air filter

3. Change to Efficiency or Hybrid mode for re-

duced energy costs

4. Ensure the cold connection is at the bottom

and that the hot connection is at the top

5. Insulate exposed piping

6. Repair hot water leaks

7. Drain and flush tank. Water conditioning may

be required to minimze build up

DRIP FROM TEMPERATURE &
PRESSURE RELIEF VALVE
(Warning: Do not plug or cap
T&P discharge pipe.)

1. Excessive water pressure

2. Add or service a thermal expansion

tank.

3. Non-functioning

Temperature

&

Pressure Relief Valve

1. Check water supply inlet pressure. If higher than

80 PSIG, install a pressure reducing valve (50-

60 PSIG is the recommended pressure.)

2. See “Closed System/Thermal Expansion” section

3. Replace the Temperature & PressureRelief

Valve

OTHER

1. The water heater does not

immediately start

2. The heat pump does not run in

Efficiency mode.

1. When first started the water heater takes about 8

minutes to complete a diagnostic routine

2. Contact a qualified person for service