beautypg.com

General safety – State PRG 40 NOMT User Manual

Page 2

background image

General Safety

2

WARNING

This water heater has been factory equipped to operate with

the type gas indicated in the “EQUIPPED FOR” area of the rat-

ing plate located near the gas control valve. The indicated gas

may be either Natural or Propane (L.P.). By following the con-

version instructions in this manual or the instructions near the

gas control valve, the water heater must be converted if it is to

be used with the opposite gas. DO NOT USE THIS WATER

HEATER WITH ANY GAS OTHER THAN THE ONE LISTED ON

THE MODEL RATING PLATE. Failure to use the correct gas can

cause problems which can result in DEATH, SERIOUS BODILY

INJURY, OR PROPERTY DAMAGE. If you have any questions or

doubts consult your gas supplier or gas company.

WARNING

A fire can start if combustible materials such as clothing, cleaning

materials, or flammable liquids are placed against or next to the

water heater.

WARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS

(VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES,

STORAGE, AND UTILITY AREAS, ETC): Flammable liquids (such

as gasoline, solvents, propane (LP) or butane, etc.), all of which

emit flammable vapors, may be improperly stored or used in such

areas. The gas water heater pilot light or main burner can ignite

such vapors. The resulting flashback and fire can cause death or

serious burns to anyone in the area, as well as property damage.

If installation in such areas is your only option, then the installa-

tion must be accomplished in a way that the pilot flame and main

burner flame are elevated from the floor at least 18 inches. While

this may reduce the chances of flammable vapors from a floor spill

being ignited, gasoline and other flammable substances should

never be stored or used in the same room or area containing a gas

water heater or other open flame or spark producing appliance.

NOTE: Flammable vapors may be drawn by air currents from

other areas of the structure to the appliance.

WARNING

HOTTER WATER CAN SCALD: Water heaters are intended to pro-

duce hot water. Water heated to a temperature which will satisfy

clothes washing, dish washing, and other sanitizing needs can

scald and permanently injure you upon contact. Some people are

more likely to be permanently injured by hot water than others.

These include the elderly, children, the infirm, or physically/men-

tally handicapped. If anyone using hot water in your home fits

into one of these groups or if there is a local code or state law

requiring a certain temperature water at the hot water tap, then

you must take special precautions. In addition to using the lowest

possible temperature setting that satisfies your hot water needs,

some type of tempering device, such as a mixing valve, should be

used at the hot water taps used by these people or at the water

heater. Mixing valves are available at plumbing supply or hard-

ware stores. Follow manufacturers instructions for installation of

the valves. Before changing the factory setting on the thermostat,

read the “Temperature Regulation” section in this manual.

WARNING

BEFORE LIGHTING [PROPANE (L.P.) GAS WATER HEATERS]:

Propane (L.P.) gas is heavier than air. Should there be a leak in the

system, the gas will settle near the ground. Basements, crawl spaces,

skirted areas under manufactured homes (even when ventilated),

closets and areas below ground level will serve as pockets for the

accumulation of this gas. Before attempting to light or relight the

water heater’s pilot or turning on a nearby electrical light switch, be

absolutely sure there is no accumulated gas in the area. Search for

odor of gas by sniffing at ground level in the vicinity of the appli-

ance. If odor is detected, follow steps indicated at “For Your Safety”

on the cover page of this manual then leave the premises.

WARNING

Improper installation, adjustment, alteration, service or

maintenance can cause DEATH, SERIOUS BODILY INJURY,

OR PROPERTY DAMAGE. Refer to this manual for assis-

tance or call the manufacturer whose name appears on the

rating plate for further information.

WARNING

At the time of manufacture this water heater was provided with

a combination temperature-pressure relief valve certified by a

nationally recognized testing laboratory that maintains periodic

inspection of production of listed equipment or materials, as

meeting the requirements for Relief Valves and Automatic Gas

Shutoff Devices for Hot Water Supply Systems, and the current

edition of ANSI Z21.22 and the code requirements of ASME. If

replaced, the valve must meet the requirements of local codes,

but not less than a combination temperature and pressure relief

valve certified as meeting the requirements for Relief Valves

and Automatic Gas Shutoff Devices for Hot Water Supply

Systems, ANSI Z21.22 by a nationally recognized testing labo-

ratory that maintains periodic inspection of production of listed

equipment or materials.

The valve must be marked with a maximum set pressure not to

exceed the marked hydrostatic working pressure of the water

heater (150 lbs. p.s.i.) and a discharge capacity not less than

the water heater input rate as shown on the model rating

plate. (Electric heaters - watts divided by 1000 x 3412 equal

BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the use of a

temperature-pressure relief valve complying with ANSI Z21.22

and ASME, may require a valve model different from the one

furnished with the water heater.

Compliance with such local requirements must be satisfied by

the installer or end user of the water heater with a locally pre-

scribed temperature-pressure relief valve installed in the desig-

nated opening in the water heater in place of the factory fur-

nished valve.

For safe operation of the water heater, the relief valve must not

be removed from it’s designated opening or plugged.

The temperature-pressure relief valve must be installed directly

into the fitting of the water heater designated for the relief

valve. Position the valve downward and provide tubing so that

any discharge will exit only within 6 inches above, or at any

distance below the structural floor. Be certain that no contact is

made with any live electrical part. The discharge opening must

not be blocked or reduced in size under any circumstances.

Excessive length, over 30 feet, or use of more than four elbows

can cause restriction and reduce the discharge capacity of the

valve.

No valve or other obstruction is to be placed between the

relief valve and the tank. Do not connect tubing directly to dis-

charge drain unless a 6

air gap is provided. To prevent bodily

injury, hazard to life, or property damage, the relief valve must

be allowed to discharge water in quantities should circum-

stances demand. If the discharge pipe is not connected to a

drain or other suitable means, the water flow may cause prop-

erty damage.

The Discharge Pipe:

—Must not be smaller in size than the outlet pipe size of the

valve, or have any reducing couplings or other restrictions.

—Must not be plugged or blocked.

—Must be of material listed for hot water distribution.

—Must be installed so as to allow complete drainage of both

the temperature-pressure relief valve, and the discharge pipe.

—Must terminate at an adequate drain.

—Must not have any valve between the relief valve and tank.

This manual is related to the following products: