Installing the new water heater (cont’d), Installation checklist – State PRG 40 NOMT User Manual
Page 15
Installation Checklist
BEFORE LIGHTING THE PILOT:
1. Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for
gas leaks using a match or open flame.
b. Brush the soapy water solution on all gas pipes,
joints and fittings.
c. Check for bubbling soap. This means you have
a leak. Turn “OFF” gas and make the necessary
repairs.
d. Recheck for leaks.
e. Rinse off soapy solution and wipe dry.
2. Is the new temperature-pressure relief valve prop-
erly installed and piped to an adequate drain? See
“Temperature-Pressure Relief Valve” section.
3. Are the cold and hot water lines connected to the
water heater correctly? See “Water Piping” instruc-
tions in the “Installing the New Water Heater”
section.
4. Is the water heater completely filled with water?
See “Filling the Water Heater” instructions in the
“Installing the New Water Heater” section.
5. Will a water leak damage anything? See the
“Locating the New Water Heater” section.
VENT PIPE TO UL
LISTED ROOF JACK
PIPE CAP
HOT
COLD
DRIP LEG
(Sediment trap)
GAS SUPPLY
SHUTOFF VALVE
DRAIN VALVE
TEMPERATURE-PRESSURE
RELIEF VALVE
TEE
SHUTOFF
VALVE
DISCHARGE PIPE
(Do not cap or plug.
Must terminate beneath
manufactured home.)
MODEL RATING PLATE
6 . Is there proper clearance between the water
heater and anything that might catch fire? See the
“Locating the New Water Heater” section.
7. Do you have adequate ventilation so that the
water heater will operate properly? See the
“Locating the New Water Heater” section.
8 . Is the draft hood vent piping properly secured?
See “Venting” instructions in the “Installing the
New Water Heater” section.
9. Is there proper clearance between the vent pipe
and anything that might catch on fire? See
“Venting” instructions in the “Installing the New
Water Heater” section.
10. Is the vent pipe properly sloped and does the vent
terminate outdoors? See “Venting” instructions in
the “Installing the New Water Heater” section.
11. Do you need to call your gas company to check
the gas pipe and its hookup?
Installing the New Water Heater (cont’d)
15
AUTOMATIC STORAGE WATER HEATER FOR
INSTALLATION IN A MANUFACTURED HOME
ORIFICE SIZE: #40 FOR NAT. / #52 FOR LP
IF CONVERTED - PROPANE RATE: 30,000 BTU
SUITABLE FOR WATER (POTABLE)
HEATING ONLY
*
* For 30 and 40 Gal. heater as shown
For 50 Gal. heater:
ORIFICE SIZE: #35 FOR NAT. / #51 FOR LP
IF CONVERTED - PROPANE RATE: 38,000 BTU