Calibrating your sprayer – Ag Spray Equipment RM55 User Manual
Page 3
3
CALIBRATING YOUR SPRAYER
HAMILTON NOZZLE 654101
CALIBRATING YOUR SPRAYER
To determine pressure & GPA with a boomless nozzle use this calibration formula.
GPA =
495 x GPM
MPH x Swath in feet
EXAMPLE:
495(constant) x 4.2GPM = 2079
4mph x 50ft swath = 200
2079
200
= 10.395 GPA
Refer to Chart
OPERATING DATA OF 180° NOZZLES
SPRAYERS ARE SUPPLIED WITH #10
GPM
Swath
GALLON PER ACRE
Office
Number
PSI
180°
180°
3 MPH
4 MPH
5 MPH
8 MPH
10 MPH
30
3.7
50 ft.
12.2
9.2
7.3
4.6
3.7
40
4.2
50 ft.
13.9
10.4
8.3
5.2
4.2
50
4.6
52 ft.
14.6
10.9
8.8
5.5
4.4
#10
60
5.0
52 ft.
15.8
11.9
9.5
5.9
4.8
GPM
=
Gallons Per Minute
GPA
=
Gallons Per Acre
MPH
=
Miles Per Hour
PSI
=
Pressure Per Square Inch
See also other documents in the category Ag Spray Equipment Water equipment:
- AG15COOP (3 pages)
- AG15COOPK (3 pages)
- AG15COOPTHPL (3 pages)
- AG15COOPTHPLK (3 pages)
- AG15DLX (3 pages)
- AG15DLXRG (4 pages)
- AG15TH (3 pages)
- AG15THPL (3 pages)
- AG15THPLE (3 pages)
- AG25LG2FHGE-BA (4 pages)
- AG25LG2FHGE-DB (4 pages)
- AG25LG2FHGE-GR (4 pages)
- AG25LG2FHGTP-BA (4 pages)
- AG25LG2FHGTP-DB (4 pages)
- AG25LG2FHGTP-GR (4 pages)
- AG25LG2FHGTPK-BA (4 pages)
- AG25LG2FHGTPK-DB (4 pages)
- AG25LG2FHGTPK-GR (4 pages)
- AG25LG5FHGD-BA (4 pages)
- AG25LG5FHGD-DB (4 pages)
- AG25COOP (3 pages)
- AG25COOPTHPL (3 pages)
- AG25COOPTHPLK (3 pages)
- AG25DLXF (3 pages)
- AG25DLXFK (3 pages)
- AG25DLXS (3 pages)
- AG25TH (3 pages)
- AG25THPL (3 pages)
- AG25THPLE (3 pages)
- AG55DLXSF (4 pages)
- AG15LG2FHGE-BA (4 pages)
- AG15LG2FHGE-DB (4 pages)
- AG15LG2FHGE-GR (4 pages)
- AG15LG2FHGTP-BA (4 pages)
- AG15LG2FHGTP-DB (4 pages)
- AG15LG2FHGTP-GR (4 pages)
- AG25LG5FHGD-GR (4 pages)
- AG25LG5FHGE-BA (4 pages)
- AG25LG5FHGE-DB (4 pages)
- AG25LG5FHGE-GR (4 pages)
- AG25LG5FHGTP-BA (4 pages)
- AG25LG5FHGTP-DB (4 pages)
- AG25LG5FHGTP-GR (4 pages)
- AG25LGFKLCHGE-BA (4 pages)
- AG25LGFKLCHGE-DB (4 pages)