Outback Power Systems MATE Serial Communications Guide User Manual
Page 16
![background image](/manuals/407195/16/background.png)
Mate Serial Communication Guide
Copyright 2007
© OutBack Power Systems, Inc.
19009 62
nd
Ave NE, Arlington WA 98223 USA
Page 16
of 20
Rev 4.04 10/21/08 Tel 360 435 6030 Fax 360 435 6019
32. Hundreds digit of state of charge.
33. Tens digit of state of charge.
34. Ones digit of state of charge.
35. ASCII (44) a comma as a data separator.
36. Shunt A enabled flag.
37. Shunt B enabled flag.
38. Shunt C enabled flag.
39. ASCII (44) a comma as a data separator.
40. High byte of status flags.
41. Low byte of status flags.
42. ASCII (44) a comma as a data separator.
43. Tens digit of battery temperature.
44. Ones digit of battery temperature.
45. ASCII(44) a comma as a data separator.
46. Hundreds digit of Chksum.
47. Tens digit of Chksum.
48. Ones digit of Chksum.
49. ASCII (13) carriage return. Denotes end of status page.
FLEXnet DC Address: The address will correspond to the HUB port the FLEXnet DC is plugged into.
Ascii(97) – Ascii(106) for Ports 1-10.
Shunt ‘A’ current ‘0000’ to ‘9999’ amps, in tenth amp increments.
Shunt ‘B’ current ‘0000’ to ‘9999’ amps, in tenth amp increments.
Shunt ‘C’ current ‘0000’ to ‘9999’ amps, in tenth amp increments.