Aurora Electronics MAGNETEK PVI-3600-OUTD-UK-F-W User Manual

Page 54

background image

Installation and Operator’s Manual

Page 54 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)


6) Press the key for longer than 5 sec. to confirm the chosen BAUD RATE
shown on the display.
Press it for a shorter time to come back to the previous display.

NOTE: Generally the standard speed to be chosen is 19200 Baud. Only in
presence of particularly long or noisy lines a lower speed is recommended.

6.8 Measurement

Accuracy

All measurement device have errors.
For each reading the following table shows:

Description and Measurement Unit
Resolution and Accuracy

Data Description Unit

Vpv1

Voltage of IN1

Vdc

Vpv2

Voltage of IN2

Vdc

Ipv1 Current

of

IN1

Adc

Ipv2 Current

of

IN2

Adc

Pac

Output Ac power

W

E-Total Total

energy

Wh

E-Today Daily

energy

Wh

h-Total Total

time

hh:mm:ss

TimeGrid

Total time energy exported to the grid

hh:mm:ss