SYSTEM REQUIREMENTS
POWER SUPPLY
The 2940 system uses a switched power source. The 2940-153 will need connected to a
switched power source. (Connector to the tractor not included)
SWITCHED POWER SOURCE CONNECTOR PART #’S:
JOHN DEERE P/N: RE67013
CNH P/N: 187103A1
FUSE PROTECTION
To protect the Compressor Assembly from damage always ensure the integrity of the
integrated 40 amp and/or 80 amp circuit breaker at the tractor cable where connected to
the battery in case of short or over-circuit. When connected correctly, the tractor has a
fuse to protect the cab controller located in the tractor’s fuse panel.
AIR COMPRESSOR MAINTENANCE
To prolong life expectancy of compressor, clean filter by removing the element from the
housing, and tapping it, exposed side down. This will empty the pleats of the filter of
collected dust. If the dust has been wet or will not clean out, call Yetter to order a new
element. You may lightly blow out the electronic box using an air tool. The housing and
filter should be checked every two days of field operation, or more if conditions are very
dusty.
FAILURE TO LINE UP TABS WHEN PLUGGING MALE INTO
FEMALE CONNECTORS CAN RESULT IN SHORT CIRCUIT