APPLICATION
4
This meter is designed to measure electromagnetic fields of
extremely low frequency (ELF) between 30 to 300Hz. It is
capable of measuring the electromagnetic field radiation
intensity that is produced by electric transmission equip-
ment, power lines, microwave ovens, air conditioners, re-
frigerators, computer monitors and video/audio devices to
name a few.
The magnetic field measurement unit is Tesla (T), Gauss
(G), milli-Gauss (mG) or micro-Tesla (µT).
FEATURES
•
micro-Tesla and milli-Gauss Measurement unit display .
•
Data hold and maximum hold function.
•
Low battery indicator
9
BATTERY REPLACEMENT
1. Turn off the instrument.
2. Remove the battery cover.
3. Replace the battery.
4. Install the battery cover.
•
Never touch the meter to electrical cables or other dan-
gerous materials.
•
To clean the EMF Meter use a soft dry cloth. Never use
a wet cloth, solvents or water, etc.
•
Operation Altitude: Up to 2000M.
•
Operating Environment: Indoor use. This instrument has
been designed for use in a pollution environment of
degree 2.
NOTES & PRECAUTIONS
Caution: this symbol indicates that equip-
ment and its accessories are subject to a
separate collection and correct disposal.