Schumacher PI-100SL User Manual
Page 6
6
TROUBLESHOOTING
PROBLEM: RED LED is on.
Reason/Solution
1.
Too much power draw.
Unplug and reinsert PI-100SL.
Use a smaller device or use a larger inverter.
2.
Inverter is too hot.
Increase ventilation to inverter.
Move inverter to a cooler area.
Reduce the power consumption of the device.
Inverter will automatically reset after cooling.
.
Input voltage is too high or too low.
Verify you are using a 12V power source with a voltage
between 10.5 – 15.0V DC.
PROBLEM: LEDs do not light, inverter does not
function.
Reason/Solution
1.
Poor contact at terminals.
Unplug and reinsert PI-100SL.
2.
fuse blows
A blown fuse is usually caused by reverse polar-
ity or a short circuit within the inverter. To replace,
remove the old fuse and insert a new 15 amp fuse
(mini spade type).
.
Inverter may be defective.
See warranty and call Customer Service 800-621-
5485 (Hours: 7 a.m. – 4:0 p.m. CST).