MJM Yachts 40z Express User Manual
Page 63

CHAPTER 16
QUICK START GUIDE
1 - Disconnect Shore-side Connections
To disconnect shore power cords, turn off all AC loads on the boat and make
sure the main AC breakers on the AC panel (the double breakers) are all OFF.
Then disconnect the cord at the dock end first. Disconnect the cord at the boat
and close the shore power inlet cover. Ditto for any phone/cable TV lines and
dock water inlet..
2 - Set Battery Switches
The Engine battery selector switches are on the AC electrical panel. Slide the
covers down and Push Start STBD engine switch and Start PORT engine switch,
both ON. Be sure that the HOUSE battery switch on the DC panel is also ON
position. Unless running the generator underway, the GENERATOR switch should
be OFF with the cover slid upwards. If the engine start battery is low the parallel
switch can be turned on until underway, then turned OFF.
Remember to turn all switches OFF when leaving the boat, except the HOUSE
battery switch, if needed to keep the Refrigeration going.
3 - Check Engine
It is advisable to check the engine fluid levels before starting the engine. Refer to
the Owner’s Manual for instructions on lifting the engine hatch cover and checking
the oil coolant and transmission levels.
4 - Check Raw Water Seacock
Make sure that the raw water seacocks are in the position to supply the engine
with seawater for cooling. It is also advisable, once the engine is started, to
check the exhaust at the transom. You should see a surge of water every few
seconds.
5 - Visually Inspect the Engine Room
While doing other checks, it is a good idea to take a look around the engine for
loose belts, wires, oil drips or water in the bilge or anything else that may be out
of order.