8. Unbolt the down pipe isolator mount and carefully remove the factory
down pipe from the vehicle. Take care not to damage the oxygen sensors or
wiring.
Refer to Figure 6.

9. Remove the oxygen sensors, isolator mount, and gasket (on the V-band
flange) from the down pipe. Remember the oxygen sensor locations.

Installation of MBRP Inc. Performance Exhaust:


1. Install the factory oxygen sensors in the Down Pipe, taking care to place
the oxygen sensors in the correct positions. Install the V-band gasket and
the isolator mount onto the Down Pipe.


2. If installing on a vehicle already equipped with

MBRP

’s 3” cat back system

(S4200) remove the 2.5” flanged extension pipe from the front muffler. Retain
the band clamp for re-installation.


3. Carefully feed the Down Pipe over the cross member up towards the
turbocharger taking care not to damage the oxygen sensors or wiring. Feed the
oxygen sensor wiring along the original path and secure with the factory clips.
Connect the oxygen sensor wiring.
Refer to Figure 7.


4. Install the Down Pipe into the turbocharger and connect using the factory V-
band clamp. Do not completely tighten the V-band clamp.

5. Install the factory isolator mount.

6. Install the factory catalytic converter support bracket, and mesh isolator using
the factory spacers and supplied 5/16” Hardware.
Refer to Figure 8.


7. If installing on a vehicle already equipped with

MBRP

’s 3” cat back system

(S4200) install the 3” Extension Pipe in the front muffler using the existing band
clamp. Do not tighten the band clamp at this time.