beautypg.com

Manley СORE REFERENCE CHANNEL STRIP - MCORE026 and up 7/2014 User Manual

Page 12

background image

VR12 VR16

Diagram 8

Diagram 9

14. Servicing

VR11

VR9

VR6

12AX7WA

6922

TUBE LOCATION

CALIBRATION TRIM POT LOCATION

c

o

r

e

11

TEST POINT LOCATION

VR15

GR-ZERO

GR-METER GR-AUDIO

2 Amp Slow-Blow (T)

20mm Ceramic FUSE

LIM CV

LIM REF V OP1 ZERO VU

15. Core Calibration Procedure

The CORE requires calibration for 3 sections of its circuitry:

I) VU METER- Adjust: +4dBu (1.228 Volts RMS) = “0” VU, Meter “GR” zero set

®

ii) ELOP COMPRESSOR - Adjust: Gain Reduction (Audio & Meter GR)
iii) FET PEAK LIMITER - Adjust: reference voltage & FET control voltage

Tools required:

-

Audio Tone Generator (oscillator)

-

Audio Analyzer or a voltmeter capable of reading both DC & AC voltages.

Initial settings:

-

Mic/Line Input select switch: Out = LINE IN Enable

-

120Hz HP filter switch: Out = Disable

-

Gain switch: Out = LOW

-

48V Phantom switch: Out = OFF

-

Phase Invert switch: Out = 0

-

Input Level Attenuator: Set at Minimum

-

Compressor Section: Switch = Bypass; Compression = MAX, Attack & Release = FAST

-

Shelving EQ section: High/Low controls set both = 12:00 o'clock.

-

Mid EQ section: Boost/Cut control = 12:00 O'clock, Frequency range select switch = 100Hz-1kHz,

Frequency sweep control = MIN

-

Peak Limiter section: Limiting = MIN, Release = 12:00 o'clock

-

Output Gain Control: 12:00 o'clock