Race Application
- Calibrate before first installation of new sensor
- Calibrate once per race weekend
3
Boost Controller Setup
3.1
Entering Setup Configuration
The SCG-1 can be configured directly from the gauge itself or by connecting
it to a computer with the LM Programmer software.
3.1.1
Configuration using SCG-1’s interface buttons
1. From the main screen, press and HOLD the left interface button to
put the gauge in setup mode
2. Pressing either the left or right interface buttons will allow you to
cycle through the 14 different setup parameters in the menu.
3. Once the desired setup parameter is displayed, press and HOLD the
left interface button to make a change. Once the parameter’s
configuration has been entered it will start flashing.
4. Make changes by using the left or right interface buttons.
5. Once in setup mode, pressing and HOLDING both interface buttons
together will move you to the menu or main screen. The gauge will
revert back to the main screen if no there have been no button
presses for 15 seconds.
3.1.2
Configuration using the LM Programmer software
Refer to chapter 4, Logworks 3 & LM Programmer Software Package to gain
access to the software.
1. Connect the OUT port of the SCG-1 to the provided serial
programming cable. Connect the other end of the serial
programming cable to your computer. If your computer does not
have a serial port, you can purchase a USB to Serial adapter from
Innovate Motorsports (P/N 3733) or use any USB to serial adaptor
that includes drivers. Make sure that nothing is connected to the IN
port of the SCG-1
2. Power up the SCG-1.
3. Launch LM Programmer. The LM Programmer application can be
launched from Start->Programs->LogWorks3->LM Programmer from
the Windows task bar.