8 hardware monitor, 26 chapter 2: bios setup – Asus K8S-MX User Manual
Page 62
2-26
Chapter 2: BIOS Setup
2.5.8 Hardware Monitor
CPU Temperature [xxx ºC/xxx ºF]
MB Temperature [xxx ºC/xxx ºF]
The onboard hardware monitor automatically detects and displays the
motherboard and CPU temperatures. Select Disabled if you do not wish to display
the detected temperatures.
CPU Fan Speed [xxxxRPM] or [N/A]
Chassis Fan Speed [xxxxRPM] or [N/A]
The onboard hardware monitor automatically detects and displays the CPU and
chassis fan speeds in rotations per minute (RPM). If any of the fans is not
connected to the motherboard, the specific field shows N/A.
VCORE Voltage, +3.3V Voltage, +5V Voltage, +12V Voltage
The onboard hardware monitor automatically detects the voltage output through
the onboard voltage regulators.
Hardware Monitor
CPU Temperature
[40.5ºC/102.5ºF]
MB Temperature
[33ªC/91ºF]
CPU Fan Speed
[3260RPM]
Chassis Fan Speed
[N/A]
VCORE Voltage
[ 1.504V]
3.3V Voltage
[ 3.360V]
5V Voltage
[ 5.160V]
12V Voltage
[11.328V]
If any of the monitored items is out of range, the following error message
appears: “Hardware Monitor found an error. Enter Power setup menu for
details”. You will then be prompted to “Press F1 to continue or DEL to enter
SETUP”.