Advance planning for custom hood inserts – GE ZVC48LSS User Manual
Page 2
64
Advance planning for custom hood inserts
The supplied liner
These hood inserts are designed for easy installation into a
variety of custom hood applications. The hood attaches directly
to the house ducting from within the unit.
• The custom canopy must be constructed to house the
insert sleeve.
• The sleeve has locking clips on the bottom edge to hold
it in place. The opening must be constructed of 3/4"-thick
material to allow the locking clips to engage.
• The opening must be sized accurately to accept the insert
sleeve and the supplied or custom liner.
• Always maintain the 1/2" dimension at the rear to ensure
correct alignment of the ductwork.
• If you are not using the supplied liner you may construct a
custom non-combustible liner. The custom liner must be
constructed to the dimensions shown to fit the insert sleeve.
• These hood inserts must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation instructions.
Refer to the installation instructions for details.
*Opening
*Custom cabinet frame cutout opening must
be 26" W x 13-3/16" D for 30" and 36"
models and 38-3/4" W x 13-3/16" D for 48"
models. To support the weight of the insert
sleeve and to allow for the temporary
locking clips to engage, the minimum
recommended thickness of the bottom
cabinet surface should be 3/4".
Product dimensions and clearances
Models ZVC36 and ZVC30
Models ZVC48 and ZVC42
ZVC30 and ZVC36
27-1/2"
14"
ZVC48
14"
39-1/2"
Remote location for the control
The control panel may be removed from the hood and installed
into a wall or countertop. A 30-ft. length of wire is supplied to
accommodate most installations. A blanking plate covers the
opening when the controls are removed.
The overall size of the control panel is 4-1/4" wide and 2-1/4" deep.
Control Cutout
3-11/16"
1-11/16"
We recommend that the cutout in granite or other hard surfaces
be made before the countertop is installed.
ZVC30 and ZVC36
16-3/4"
25-3/4"
13"
14"
7/8"
1/2"
1/2"
NOTE: Bottom edge of insert sleeve
has a 7/8" flange on each side and
a 1/2" flange on both front and back.
The bottom edge of the insert sleeve has a 7/8"-wide flange on the
sides and 1/2"-wide flange on the front and back.
Note: 1/2" flange surrounds outside edge of insert sleeve.
ZVC48
38-1/2"
13"
14"
29-1/2"
1/2"
1/2"
1/2"
NOTE: 1/2" flange surrounds
outside edge of insert sleeve.
A B
width width
ZVC30LSS 1-1/4" 28-1/2"
ZVC36LSS 4-1/4" 34-1/2"
ZVC42LSS 7/8" 40-1/2"
ZVC48LSS 3-7/8" 46-1/2"
Custom cabinet opening
width depth
ZVC30LSS 26" 13-3/16"
ZVC36LSS 26" 13-3/16"
ZVC42LSS 38-3/4" 13-3/16"
ZVC48LSS 38-3/4" 13-3/16"
Custom insert liner
Use the same opening cabinet dimensions to construct a custom
liner. 3/4"-thick material must surround the opening. The 1/2"
dimension at the rear is necessary to ensure duct alignment.
3/4"-thick material