Installation instructions, Caution, Warning – GE JV394SBB User Manual
Page 4: Tools you will need, Plan the installation, Install the hood
4
INSTALLATION INSTRUCTIONS
TOOLS YOU WILL NEED
Flat blade and Phillips
screwdrivers
Pencil
Duct tape
Saw (saber or keyhole)
Electric drill
Metal snips
(in some applications)
Pliers
Tape measure
Wire stripper
Flashlight
Caulking
Level
PLAN THE INSTALLATION
CAUTION:
Remove the house fuse or open
the circuit breaker before beginning the installation.
recessed bottom, framed or frameless kitchen cabinet which has a minimum depth of 11s from the face to the inside of the back wall. see the instructions. 24s above the cooking surface. For easiest installation, the range hood should be installed in the cabinet before mounting the cabinet to the wall. hood in the cabinet to protect the visor from damage. hood, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. INSTALL THE HOOD 1. Mark and cut out the cabinet bottom. Prepare the cabinet bottom as shown above. Be sure to locate the cut-out and four holes from the front of the cabinet to ensure a flush mount. DUCT EQUIVALENT NUMBER PIECES LENGTH X USED = TOTAL 3 1 ø 4 s x 10s 1 Ft. x ( ) = Ft. Rect., straight 3 1 ø 4 s x 10s 14 Ft. x ( ) = Ft. Rect. 90° elbow 3 1 ø 4 s x 10s 8 Ft. x ( ) = Ft. Rect. 45° elbow 3 1 ø 4 s x 10s 33 Ft. x ( ) = Ft. Rect. 90° flat elbow 3 1 ø 4 s x 10s 24 Ft. x ( ) = Ft. Rect. (18 ft. w/o wall cap damper) x ( ) = Ft. with damper Total ductwork = Ft. :25.6+((7³&$/&8/$7(727$/ EQUIVALENT DUCTWORK LENGTH MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 3 1 ø 4 s x 10s rectangular duct should not exceed 65 equivalent feet. 7KLVKRRGFDQHDVLO\EHLQVWDOOHGE\IROORZLQJWKHVHEDVLFVWHSV • Mark and cut out the cabinet bottom. • Secure the hood to the cabinet. • Mount the cabinet on the wall. • Connect the ductwork and the power cable. WARNING – TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.
The unit is ducted vertically. To change to horizontal ducting
For safe operation, the mounted hood must be a minimum of
NOTE: Remove the glass visor from the unit before installing the
NOTE: Any home ventilation system, such as a ventilation