Should the plug need to be replaced
for any reason, proceed as described
below.
The wires in the mains lead are
coloured in accordance with the
following code:

• The wire coloured green and yellow

must be connected to the terminal
marked with the letter “E“ or by the
earth symbol

E or coloured green and yellow.

• The wire coloured blue must be connected to the terminal “N“ or

coloured black.

• The wire coloured brown must be connected to the terminal marked

“L“ or coloured red.

• Upon completion there must be no cut, or stray strands of wire

present and the cord clamp must be secure over the outer sheath.

1

WARNING! A cut off plug inserted into a 13 amp socket is a serious
safety (shock) hazard. Ensure that the cut off plug is disposed of safely.

Permanent Connection

In the case of a permanent connection it is necessary that you install a
double pole switch between the appliance and the electricity supply
(mains), with a minimum gap of 3mm between the switch contacts and
of a type suitable for the required load in compliance with the current
electrical regulations.
The switch must not break the yellow and green earth cable at any
point.
This appliance complies with the requirements laid out in the EEC Di-
rective 76/899.
Voltage 240 V AC: Fuse rating 13amps
See rating plate for further information.
This appliance meets VDE requirements.
Particular regulations of local electricity authorities must be observed.
This appliance conforms to EEC Directive No. 82/499/EWG on radio in-
terference.

Green and Yellow:

Earth

Blue:

Neutral

Brown:

Live