beautypg.com

Installation instructions, Caution, Adapting blower for outside back exhaust b4 – GE PSA9240DFWW User Manual

Page 16

background image

BEFORE: Fan Blade

Openings Facing Up

4

3

2

1 Remove the three screws that hold the blower

plate to the oven. Slide blower plate from under

its retaining flange. Remove and save the screw

that holds blower motor to oven.

ADAPTING BLOWER FOR

OUTSIDE BACK EXHAUST

B4

End B

End A

Carefully pull out the blower unit. The wires

will extend far enough to allow you to adjust

the blower unit.

Rotate blower unit counterclockwise 180°.

Before Rotation

After Rotation

Gently remove the wires from the grooves.

Reroute the wires through grooves on other side

of the blower unit.

Before Rerouting

After Rerouting

Wires Routed Through Right

Side

Wires Routed Through Left

Side

Blower Plate

Back of

Oven

Back of

Oven

Blower

Motor Screw

16

USE TOP CABINET TEMPLATE

FOR PREPARATION OF TOP

CABINET

B3

‡ Read the instructions on the TOP CABINET

TEMPLATE.

‡ Tape it underneath the top cabinet.
‡ Drill the holes, following the instructions on the

TOP CABINET TEMPLATE.

CAUTION:

Wear safety goggles when

drilling holes in the cabinet bottom.

Wall

Mounting

Plate

Spacing for Toggles More

Than Wall Thickness

Toggle

Bolt

Toggle Wings

To use toggle bolts:

Bolt End

Installation Instructions

You need to drill holes for the top support screws and

a hole large enough for the power cord to fit through.

Place the mounting plate against the wall and insert

the toggle wings into the holes in the wall to mount

the plate.

NOTE: Before tightening toggle bolts and wood screw,

make sure the tabs on the mounting plate touch

the bottom of the cabinet when pushed flush against

the wall and that the plate is properly centered under

the cabinet.

CAUTION:

%HFDUHIXOWRDYRLGSLQFKLQJ

ILQJHUVEHWZHHQWKHEDFNRIWKHPRXQWLQJ

plate and the wall.

Tighten all bolts. Pull the plate away from the wall

to help tighten the bolts.

3

4

Retaining

Flange