Installation Instructions
ADDING ELBOW AND DUCT FOR
EXHAUST TO LEFT OR RIGHT SIDE OF
CABINET
• Preassemble 4” elbow with 4” duct. Wrap duct tape
around joint.
,QVHUWGXFWDVVHPEO\HOERZ¿UVWWKURXJKWKHVLGH
opening and connect the elbow to the dryer internal
duct.
CAUTION:
Be sure not to pull or damage the
electrical wires inside the dryer when inserting the duct.
• Apply duct tape as shown on the joint between the
dryer internal duct and the elbow.
ADDING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
• Insert the elbow through the rear opening and connect
it to the dryer internal duct.
• Apply duct tape on the joint between the dryer internal
duct and elbow, as shown above.
EXHAUST CAN
BE ADDED TO
LEFT OR RIGHT SIDE
DUCT
TAPE
DUCT
TAPE
CAUTION:
Internal duct joints must be
secured with tape, otherwise
they may separate and cause a
safety hazard.
ADDING COVER PLATE TO REAR OF
CABINET (SIDES AND BOTTOM EXHAUST)
Connect standard metal elbows and ducts to complete
WKHH[KDXVWV\VWHP&RYHUEDFNRSHQLQJZLWKDSODWH.LW
:(0DYDLODEOHIURP\RXUORFDOVHUYLFHSURYLGHU3ODFH
GU\HULQ¿QDOORFDWLRQ
CAUTION:
Internal duct joints must be secured with tape,
otherwise they may separate and cause a
safety hazard.
PL ATE
(KIT WE1M454)
WARNING-
NEVER LEAVE THE
BACK OPENING WITHOUT THE PLATE
(Kit WE1M454).
5(*,67(5<2851(:$33/,$1&(725(&(,9($1<
,03257$17352'8&7127,),&$7,216
Please go to www.GEAppliances.com or mail in
your product registration card.
)RUTXHVWLRQVRQLQVWDOODWLRQFDOO86RU
&DQDGD