background image

28

SCRUBTEC 653B – 653BL – 651BCL – 661BL

9097058000(2)2009-10 A

ENGLISH

USER MANUAL

FUSE CHECK/REPLACEMENT

Disconnect the battery connector (12).

1.

Move aside the recovery water drain hose (16).

2.

Remove the battery charger cable (I, Fig. 10), if equipped, from the cable holder (J).

3.

Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel

4.

(B).
Check/replace the following fuses:

5.

Brush deck fuse F1: (40 A)

(5a)

Vacuum system fuse F2: (30 A)

(5b)

Drive system fuse F3: (30 A) (*)

(5c)

Signal circuits fuse F4: (3 A)

(5d)

Brush/pad-holder release fuse F5: (20 A)

(5e)

Pump fuse F6: (3 A)

(5f)

Only for SCRUBTEC 653BL, SCRUBTEC 651BCL, SCRUBTEC 661BL

(*)

Perform steps 1 to 4 in the reverse order.

6.