background image

Gas Convection Oven - Electronic Control

Pg. 4.

The oven must be mounted on the factory equipped

oven legs or on an optional oven stand. Installation

on a solid or concrete base that in any way restricts

air flow may void the warranty.

All clearances for a proper ventilation air supply

must be maintained to minimize fire hazard. Do

not locate the oven immediately adjacent to any

other heat-generating appliance.

A number of adjustments are associated with initial

installation and start-up. Adjustments must be

conducted by a qualified service technician.

Installation and start-up adjustments are the

responsibility of the dealer or user. These

adjustments include but are not limited to

thermostat calibration, door adjustment, leveling,

and gas pressure verification. The Platinum series

oven burners are factory-adjusted with fixed air

openings and require no field adjustment.

LEVELING

The oven should

be leveled before the gas supply

is connected. Level the oven from side-to-side and

front-to-back with the use of a spirit level. For

ovens installed on a mobile stand, it is important

that the floor surface be level due to the probability

of frequent oven repositioning.

We recommend checking the level of the oven

periodically to make certain the floor has not

shifted nor the oven moved.

NOTE:

Failure to properly level this oven can

cause improper function as a result of

erratic burner combustion and will result

in the uneven baking of products

consisting of semi-liquid batter.

I N S T A L L A T I O N R E Q U I R E M E N T S

3

0

-5

/8

"

(7

7

8

m

m

)

4

4

-1

/2

"

(1

1

3

0

m

m

)

5

8

-1

/2

"

(1

4

8

6

m

m

)

3

1

-1

5

/1

6

"

(8

1

0

m

m

)

38" (965mm)

25-11/16" (652mm)

3-5/16" (84,4mm)

29-1/8" (740mm)

3/4"
GAS INLET
3-5/32"
(80,1mm)

8

-1

/2

"

(2

1

5

m

m

)

9

-1

5

/1

6

"

(2

5

2

m

m

)

L

IN

E

C

O

R

D

E

N

T

R

A

N

C

E

3

1

-1

/1

6

"

(7

8

9

m

m

)

4" (102mm)

3/4" GAS INLET

EXHAUST
VENT

CAVITY WIDTH

123

°

129

°

2

6

-1

/2

"

(6

7

3

m

m

)

5

4

-5

/8

"

(1

3

8

7

m

m

)

3-11/16" (93mm)

6' (1828mm)

LINE CORD ENTRANCE

1

2

-1

5

/1

6

"

(3

2

9

m

m

)

I N S T A L L A T I O N

W A R N I N G

Inadequate ventilation, or failure to
ensure an adequate supply of fresh
air will result in a high ambient
temperature at the rear of the
appliance. An excessive ambient
temperature can cause the thermal-
overload protection device on the
blower motor to trip resulting in severe
damage to the blower motor.

C A U T I O N

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

MODEL ASC-4G

Electronic Control