Gas Convection Oven - Electronic Control
Pg. 4.
The oven must be mounted on the factory equipped
oven legs or on an optional oven stand. Installation
on a solid or concrete base that in any way restricts
air flow may void the warranty.
All clearances for a proper ventilation air supply
must be maintained to minimize fire hazard. Do
not locate the oven immediately adjacent to any
other heat-generating appliance.
A number of adjustments are associated with initial
installation and start-up. Adjustments must be
conducted by a qualified service technician.
Installation and start-up adjustments are the
responsibility of the dealer or user. These
adjustments include but are not limited to
thermostat calibration, door adjustment, leveling,
and gas pressure verification. The Platinum series
oven burners are factory-adjusted with fixed air
openings and require no field adjustment.
LEVELING
The oven should
be leveled before the gas supply
is connected. Level the oven from side-to-side and
front-to-back with the use of a spirit level. For
ovens installed on a mobile stand, it is important
that the floor surface be level due to the probability
of frequent oven repositioning.
We recommend checking the level of the oven
periodically to make certain the floor has not
shifted nor the oven moved.
NOTE:
Failure to properly level this oven can
cause improper function as a result of
erratic burner combustion and will result
in the uneven baking of products
consisting of semi-liquid batter.
I N S T A L L A T I O N R E Q U I R E M E N T S
3
0
-5
/8
"
(7
7
8
m
m
)
4
4
-1
/2
"
(1
1
3
0
m
m
)
5
8
-1
/2
"
(1
4
8
6
m
m
)
3
1
-1
5
/1
6
"
(8
1
0
m
m
)
38" (965mm)
25-11/16" (652mm)
3-5/16" (84,4mm)
29-1/8" (740mm)
3/4"
GAS INLET
3-5/32"
(80,1mm)
8
-1
/2
"
(2
1
5
m
m
)
9
-1
5
/1
6
"
(2
5
2
m
m
)
L
IN
E
C
O
R
D
E
N
T
R
A
N
C
E
3
1
-1
/1
6
"
(7
8
9
m
m
)
4" (102mm)
3/4" GAS INLET
EXHAUST
VENT
CAVITY WIDTH
123
°
129
°
2
6
-1
/2
"
(6
7
3
m
m
)
5
4
-5
/8
"
(1
3
8
7
m
m
)
3-11/16" (93mm)
6' (1828mm)
LINE CORD ENTRANCE
1
2
-1
5
/1
6
"
(3
2
9
m
m
)
I N S T A L L A T I O N
W A R N I N G
Inadequate ventilation, or failure to
ensure an adequate supply of fresh
air will result in a high ambient
temperature at the rear of the
appliance. An excessive ambient
temperature can cause the thermal-
overload protection device on the
blower motor to trip resulting in severe
damage to the blower motor.
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
MODEL ASC-4G
Electronic Control