6

SECONDARY

RETURN

COMBINATION
VALVE

EXPANSION RELIEF

PIPE

COLD

MAINS-IN

22mm

DRAIN

EXPANSION
VESSEL

PRESSURE + TEMPERATURE
RELIEF VALVE

HOT SUPPLY

22mm

TUNDISH

22mm

MAX. 100mm

F

IG

. 2.2

2.7

C

ONNECTION OF

M

AINS

W

ATER

S

UPPLY

For floor standing models:
On the front of the unit there is a label to identify the connection ports.
Please check this before making any connection to the unit.

For units up to 300 litres it is recommended that all mains cold water supply
pipe work is a minimum of 22mm, with the exception of model ST 50
ProTech where 15mm can be used. For 500 litre models the supply should
be 28mm. An isolating valve should be installed between the cold water
supply and the cylinder for servicing. ALL PIPEWORK MUST BE FLUSHED
TO AVOID DAMAGE TO THE CONTROL VALVES.

Please refer to

F

IGS

. 2.1, 2.2, 2.3, 2.4, 2.5 for a suggested installation layout.

STD P

RO

T

ECH

100

STD/STD P

RO

T

ECH

/ITD 125-150-210-300 D

IRECT

COMBINATION

VALVE

EXPANSION

RELIEF

PIPE

COLD

MAINS-IN

15/22mm

EXPANSION
VESSEL

PRESSURE + TEMPERATURE
RELIEF VALVE

HOT SUPPLY

15/22mm

TUNDISH

15mm

22mm

MAX. 100mm

F

IG

. 2.1

ST P

RO

T

ECH

50-80-100