beautypg.com

Installing a dimm, Hot-plug sas hard drive options – HP ProLiant DL380 G6 Server User Manual

Page 48

background image

Hardware options installation 48

Installing a DIMM

CAUTION:

To avoid damage to the hard drives, memory, and other system components, the air

baffle, drive blanks, and access panel must be installed when the server is powered up.

1.

Power down the server (on page

22

).

2.

Extend the server from the rack (on page

22

).

3.

Remove the access panel (on page

23

).

4.

Remove the air baffle.

5.

Open the DIMM slot latches.

6.

Install the DIMM.

7.

Install the air baffle ("

Remove the air baffle

" on page

27

).

8.

Install the access panel (on page

24

).

If you are installing DIMMs in mirrored or lock-step configuration, configure this mode in RBSU ("

HP

ROM-Based Setup Utility

" on page

66

).

For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display LED

combinations (on page

10

)."

Hot-plug SAS hard drive options

When adding hard drives to the server, observe the following general guidelines:

The system automatically sets all device numbers.

If only one hard drive is used, install it in the bay with the lowest device number.

Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.