beautypg.com

HP StorageWorks 2.128 SAN Director Switch User Manual

Page 70

background image

70

Configuring standard security features

4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch

2/32, Brocade 4Gb SAN Switch for HP p-Class BladeSystem, and SAN Switch 4/32

Follow this procedure to set the boot PROM password without a recovery string:

1.

Create a serial connection to the switch as described in ”

Connecting through the serial port

” on

page 21.

2.

Reboot the switch by issuing the

reboot

command.

3.

Press ESC within four seconds after the message

Press escape within 4 seconds...

is

displayed.
The following options are available:

4.

Enter

3

.

5.

At the shell prompt, issue the

passwd

command.

NOTE:

The

passwd

command applies only to the boot PROM password when it is entered from the

boot interface.

6.

Enter the boot PROM password at the prompt, and then reenter it when prompted. The password must

be eight alphanumeric characters (any additional characters are not recorded). Record this password

for future use.

7.

Issue the

saveEnv

command to save the new password.

8.

Reboot the switch by issuing the

reset

command.

Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director

On the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director, set the password on the

standby CP blade, fail over, and then set the password on the previously active (now standby) CP blade

to minimize disruption to the fabric:

1.

Determine the active CP blade by opening a telnet session to either CP blade, connecting as admin,

and entering the

haShow

command.

2.

Connect to the active CP blade serially and by telnet and issue the

haDisable

command to prevent

failover during the remaining steps.

3.

Create a serial connection to the standby CP blade as described in ”

Connecting through the serial

port

” on page 21.

4.

For the Core Switch 2/64: Reboot the standby CP blade by pressing the yellow ejector buttons at top

and bottom of the CP blade, and then press both ejector handles back towards the switch to lock the

blade back into the slot.
SAN Director 2/128 and 4/256 SAN Director: Reboot the standby CP blade by sliding the On/Off

switch on the ejector handle of the standby CP blade to Off, and then back to On.
This causes the blade to reset.

5.

Press ESC within four seconds after the message

Press escape within 4 seconds...

is

displayed.

Option

Description

1 Start system.

Continues the system boot process.

2 Recovery password.

Lets you set the recovery string and the boot PROM

password.

3 Enter command shell. Provides access to boot parameters.