216 Configuring the PID format

Evaluating the fabric

If there is the possibility that your fabric contains host devices with static PID bindings, evaluate the fabric

to:

Find any devices that bind to PIDs

Determine how each device driver responds to the PID format change

Determine how any multipathing software responds to a fabric service interruption

If current details about the SAN are already available, it might be possible to skip the data collection

step. If not, it is necessary to collect information about each device in the SAN. Any type of device might

be able to bind by PID; each device should be evaluated before attempting an online update. This

information has broad applicability, because PID-bound devices are not able to seamlessly perform in

many routine maintenance or failure scenarios. To evaluate the fabric:

Table 46

PID format recommendations for adding new switches

Existing Fabric OS versions;

PID format

Switch to be

added

Recommendations (in order of preference)

Version 2.6.2 and later;

version 3.1.2 and later; Native

PID

2.6.2 and

later; 3.1.2

and later

Use Native PID format for new switch. Host reboot is not

required.

Convert existing fabric to Core PID format, upgrading

the version of Fabric OS, if necessary. Set Core PID

format for new switch. Host reboot is required.

If devices are bound statically and it is not possible to

reboot, convert existing fabric to Extended Edge PID

format, upgrading the version of Fabric OS, if

necessary. Use Extended Edge PID format for new

switch. Host reboot is not required.

4.2.0 and

later

Convert existing fabric to Core PID format, upgrading

the version of Fabric OS, if necessary. Set Core PID

format for new switch. Host reboot is required.

If devices are bound statically and it is not possible to

reboot, convert existing fabric to Extended Edge PID

format, upgrading the version of Fabric OS, if

necessary. Use Extended Edge PID format for new

switch Host reboot is not required.

Version 2.6.2 and later;

version 3.1.2 and later;

version 4.2.0 and later; Core

PID

2.6.2 and

later; 3.1.2

and later;

4.2.0 and

later

Use Core PID for new switch.
Host reboot is not required.

Version 2.6.2 and later;

version 3.1.2 and later;

version 4.2.0 and later;

Extended Edge PID

2.6.2 and

later; 3.1.2

and later;

4.2.0 and

later

Use Extended Edge PID for new switch.