152 Troubleshooting

Checking fan components

1.

Log in to the switch as user.

2.

Issue the

fanShow

command.

3.

Check the fan status and speed output.
If any of the fan speeds display abnormal RPMs, replace the fan FRU.

Checking the switch temperature

1.

Log in to the switch as user.

2.

Issue the

tempShow

command.

3.

Check the temperature output. Look for indications of high or low temperatures.

Checking the power supply

1.

Log in to the switch as user.

2.

Issue the

psShow

command.

3.

Check the power supply status.
See the appropriate SAN Switch installation guide for details regarding the power supply status.
If any of the power supplies show a status other than

OK

, consider replacing the power supply as soon

as possible.

Checking the temperature, fan, and power supply

1.

Log in to the switch as user.

2.

Issue the

sensorShow

command.

See the HP StorageWorks Fabric OS 5.x command reference guide for details regarding the sensor

numbers.

3.

Check the temperature output. Look for indications of high or low temperatures.

4.

Check the fan speed output.
If any of the fan speeds display abnormal RPMs, replace the fan FRU.

5.

Check the power supply status.
If any of the power supplies show a status other than OK, consider replacing the power supply as

soon as possible.

Correcting device login issues

To try to pinpoint problems with device logins, use the following procedure:

1.

Log in to the switch as admin.

2.

Issue the

switchShow

command, and then check for correct logins.