Troubleshooting

230

HA-Fabric Manager User Guide

Problems with Zoning

The following section states some possible issues and recommended solutions for
zoning errors.

Table 20: Zoning Problems and Resolutions

Problem

Resolution

Receiving zoning errors.

Verify that you did not configure zoning on a

non-principal switch.

The application is not

performing zoning discovery

very often.

Zoning discovery is performed once at startup,

and then once every two hours during routine

discovery. If the Zoning dialog box is open,

zoning discovery is performed during every

polling cycle. It continues to discover at the

increased speed for 30 minutes before it returns

to the default value.

When activating a large zone

set on a two-switch fabric on

UNIX platforms, an error

message displays stating

“Failed to perform the

requested zoning action: Failed

to zone due to exception

COM.hp.hafmecc.HafmUnavai

lableException.”

Although the error message states that the

requested zoning action failed, the zone set

correctly activated. Wait for the next zoning

polling to occur.
This issue only occurs on UNIX systems.

Zoning activation message

displays for a long time, but

zone set is not activated.

Telnet zoning can take a long time. To improve

speed, open the Discover Setup dialog box and

add the HAFM IP address for HP switches to the

Selected Individual Addresses

list.

When opening the Zoning

dialog box from a particular

switch or fabric, the message

“Cannot zone the selected

device or fabric” displays.

The application may not have been able to log in

to the fabric due to another active session. Verify

that there isn’t another active session.
The application may not support zoning on any

of the discovered products.