13 capacity control rules syntax, Keywords—when, Writing the where rule – HP StorageWorks 2.32 Edge Switch User Manual
Page 183: Parameter, only certain, Keywords may be

Optional Features
183
■
Keywords—When writing the
where rule
parameter, only certain
keywords may be used.
Note:
Keywords are not case sensitive.
— Types
— Device
— Network
— Zone
— Fabric
— Switch, Hub, Bridge, NAS, HBA, Storage, Tape, JBOD, Loop,
Server—various types of devices
— Property Names
— Wwn—Node worldwide name
— Portwwn—Port worldwide name
— model—Device model
— IPAddress—Device IP address
— serialNumber—Device serial number
— vendor—Device vendor
— Firmware—Firmware on the device
— PortType—Port type on a device
Table 13: Capacity Control Rules Syntax
Syntax
Description
total_connections
(device = x)
‘Operator’ 2
The sum of connections to device
x
should be ‘
Operator
’ than
2total_connections.
(device = x) ‘Operator’
MAXPORTS
The sum of connections to device
x
should be ‘
Operator
’ than
MAXPORTS.
total_connections
(device = x) to
(device = y) ‘Operator’ 2
The sum of connections from
device
x
to device
y
should be
‘
Operator
’ than 2.