System maintenance switch, Mezzanine connector definitions – HP ProLiant BL420c Gen8 Server Blade User Manual

Page 9

background image

Component identification 9

Item

Description

10

Enclosure connector

11

MicroSD card connector

12

FlexibleLOM connectors (2)

13

Processor socket 1 (populated)

14

Processor 2 DIMM slots

15

Internal USB connector

16

TPM connector

The symbols

correspond to the symbols located on the interconnect bays. For more information, see the

HP ProLiant BL420c Gen8 Server Blade Installation Instructions on the HP website (

http://www.hp.com/support

).

System maintenance switch

Position

Default

Function

S1

Off

Off = iLO security is enabled.

On = iLO security is disabled.

S2

Off

Off = System configuration can be

changed.

On = System configuration is locked.

S3

Off

Reserved

S4

Off

Reserved

S5

Off

Off = Power-on password is enabled.

On = Power-on password is disabled.

S6

Off

Off = No function

On = ROM reads system configuration
as invalid.

S7

Reserved

S8

Reserved

S9

Reserved

S10

Reserved

S11

Reserved

S12

Reserved

To access redundant ROM, set S1, S5, and S6 to on.
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all

system configuration settings from both CMOS and NVRAM.

CAUTION:

Clearing CMOS and/or NVRAM deletes configuration information. Be sure to

properly configure the server or data loss could occur.

Mezzanine connector definitions

A PCIe x8 mezzanine connector supports x16 cards at up to x8 speeds.

Item

PCIe

Mezzanine connector 1

x8, Type A mezzanine card only

Mezzanine connector 2

x16, Type A or B mezzanine card