Configuration, Table 2-1, Sas cables – HP Integrity NonStop H-Series User Manual
Page 10

Installing and Configuring the Tape Drive for the
NonStop NS-Series Integrity Server
M8705A Tape Drive Installation and User’s Guide — 694638-001
2 -2
Configuration
4. Connect the CLuster I/O Module to a NonStop NS-series server.
5. Connect one end of the power cord to the unit’s AC power receptacle and connect
the other end to an AC power outlet.
6. Power on the tape drive.
Configuration
1. Issue an SCF ADD TAPE command. This is an example:
-> ADD TAPE $M8705A, SENDTO STORAGE, CLIM C1002531, LUN 1
You can specify backup and primary CPUs if you need to balance the processing
load to other CPUs.
2. After configuring the tape drive in SCF, issue the following command:
SCF> START TAPE $tape
Example:
SCF> START TAPE $M8705A
For complete details about the ADD and START commands, including command
syntax, see the SCF Reference Manual for the Storage Subsystem.
For more information on connecting tape drives to the CLIM, see the NonStop
CLuster I/O Module (CLIM) Installation and Configuration Guide.
Table 2-1. SAS Cables
Part Number
Description
AE466A
2M External Infiniband (SFF-8470) to Mini SAS (SFF-8088)
1 x SAS Cable
AE468A
4M External Infiniband (SFF-8470) to Mini SAS (SFF-8088)
1 x SAS Cable