beautypg.com

Technical data, Something not working, By-pass diameters – AEG 25742 GM User Manual

Page 12

background image

12

9

If the hob is not working correctly, please carry out the following checks before
contacting your local AEG Service Force Centre.

Something Not Working

SYMPTOM

• There is no spark when lighting

the gas

• The gas ring burns unevenly

SOLUTION

• Check that the unit is plugged in

and the electrical supply is
switched on

• Check that the RCCB has not

tripped (if fitted)

• Check the mains fuse has not

blown

• Check the burner cap and crown

have been replaced correctly, e.g.
after cleaning.

• Check the main jet is not blocked

and the burner crown is clear of
food particles.

• Check the burner cap and crown

have been replaced correctly, e.g.
after cleaning.

If after all these checks, your hob still does not operate correctly, contact your local
AEG Service Force Centre.

Please note that it will be necessary to provide proof of purchase for any in-guarantee
service calls.

In-guarantee customers should ensure that the above check have been made as the
engineer will make a charge if the fault is not a mechanical or electrical breakdown.

Technical Data

Burner

Ø Tap By-Pass 1/100 mm

Small auxiliary

27

Medium semi-rapid

29

Large rapid

39

Standard

65

By-pass diameters

Dimensions in mm:

Hob H x W x D

90 x 680 x 510

Installation opening W x D

560 x 480

Burner power in kW:
Small auxiliary burner

1,00

Medium semi-rapid burner

1,65

Large rapid burner

3,0

Triple flame burner standard

4,25

Category

II 2H3+

Gas intake connection

G 1/2”

Gas pressure

G20 - 20 mbar

Electricity supply

230 V ~ 50 Hz

Appliance class

3

MAXIMUM

MINIMUM

G 20

G30/G31

BURNER

OUTPUT

OUTPUT

20 mbar

28-30/37 mbar

TYPE

(gcv)

kW

kW

Nozzle Nominal Nozzle Nominal

marking flow rate marking flow rate
100/mm

m

3

/h

100/mm

g/h

Small aux burner

1,00

0,30

76

0,095

50

73

Medium semi-rapid b.

1,65

0,32

94

0,157

65

120

Large rapid burner

3,00

0,65

128

0,286

85

219

T.F. burner std

4,25

1,50

63+140

0,405

37+97

310