Electric models only, Grounding, Important – American Dryer Corp. T30 User Manual
Page 19: Warning, Electrical connections, For ce models only, Single-phase (1ø) wiring connections/hookup, Electrical service specifications

113429 - 9
Telephone 01422 822282
19
Electric Models Only
All electrically heated dryers must be connected to the electric
service shown on the dryer’s data label. The connecting
wires must be properly sized to handle the rated current.
Grounding
A ground (earth) connection must be provided and installed
in accordance with local, state, and national regulations or
codes of the country of origin. In the absence of these codes,
grounding must conform to applicable requirements of the
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION,
or in Canada, the installation must conform to applicable
Canada Standards: Canadian Electrical Codes Parts 1 & 2
CSA C22.1-1990 or LATEST EDITION. The ground connection
may be to a proven earth ground at the location service panel.
For added personal safety, when possible, it is suggested
that a separate ground wire (size per local codes) be
connected from the ground connection of the dryer to a
grounded cold water pipe. Do not ground to a gas pipe or hot
water pipe. The grounded cold water pipe must have
metal-to-metal connection all the way to the electrical ground.
If there are any nonmetallic interruptions, such as, a meter,
pump, plastic, rubber, or other insulating connectors, they
must be jumped out with a wire (size per local codes) and
securely clamped to bare metal at both ends.
Important
For personal safety and proper operation, the
dryer must be grounded.
Provisions are made for ground connection in each dryer at
the electrical service connection area.
Warning
Electrical Grounding Instructions – This dryer is
equipped with a 3-prong (grounding) plug for your
protection against shock hazard and should be plugged
directly into a properly grounded 3-prong receptacle. Do
not cut or remove the grounding prong from this plug.
Electrical Connections
A wiring diagram is located behind the control panel for
connection data.
If local codes permit, power to the dryer can be made by the
use of a flexible UL listed power cord/pigtail (wire size must
conform to rating of dryer), or the dryer can be hard wired
directly to the service breaker panel. In both cases, a strain
relief must be installed where the wiring enters the dryer.
For CE Models Only
The means for disconnection from the supply must be
incorporated into wiring having a minimum contact separation
of 3.0mm in all poles.
Single-Phase (1ø)
Wiring Connections/Hookup
The electrical input connections are made into the rear service
box located at the upper right area of the dryer. The ground
connection is made to the copper lug, also provided in this
box. To gain access, the service box cover must be removed.
!
!
7/15/08
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5
ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical
Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
OVEN
kW
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
T20
200
1ш
2
5.6
32.7
32.7
45
208
1ш
2
4.1
24.2
—
35
208
1ш
2
6.1
34.0
—
45
220
1ш
2
6.8
35.6
—
45
230
1ш
2
5.0
—
26.4
35
230
1ш
2
7.4
—
36.8
50
240
1ш
2
5.4
27.1
—
35
240
1ш
2
8.1
38.4
38.4
50
208
3ш
3
6.5
22.7
—
30
240
3ш
3
7.5
22.6
—
30
380
3ш
4
6.8
—
15.0
20
400
3ш
4
7.5
—
15.5
20
416
3ш
4
8.1
—
15.8
20
T30
200
1ш
2
12.5
68.4
67.7
90
208
1ш
2
7.9
43.8
—
60
208
1ш
2
13.5
70.7
—
90
230
1ш
2
8.3
—
41.3
60
230
1ш
2
12.4
—
59.1
80
240
1ш
2
9.0
42.7
—
60
240
1ш
2
13.5
61.5
—
80
208
3ш
3
13.5
43.3
—
60
220
3ш
3
11.3
35.3
—
50
230
3ш
3
12.4
—
36.5
50
240
3ш
3
13.5
37.7
—
50
380
3ш
4
11.3
22.8
22.6
40
400
3ш
4
12.4
—
23.1
40
416
3ш
4
13.5
—
23.7
40
T50
200
1ш
2
14.8
82.1
—
110
208
1ш
2
16.0
85.1
—
110
220
1ш
2
13.4
68.8
69.4
90
230
1ш
2
14.7
—
72.3
100
240
1ш
2
16.0
74.2
75.1
100
200
3ш
3
14.8
—
51.0
70
208
3ш
3
16.0
52.6
—
70
220
3ш
3
13.4
43.0
43.6
60
230
3ш
3
14.7
—
45.3
60
240
3ш
3
16.0
46.0
—
60
380
3ш
4
13.4
28.0
28.6
40
400
3ш
4
14.8
—
29.8
40
416
3ш
4
16.0
—
30.7
40
T50 Dual Voltage 480 / 120
120
1ш
2
0.0
13.2
—
15
480
3ш
3
16.0
19.2
—
25
T50 Dual Voltage 480 / 240
240
1ш
2
0.0
6.5
—
15
480
3ш
3
16.0
19.2
—
25
T50 Dual Voltage 600 / 120
120
1ш
2
0.0
13.2
—
15
600
3ш
3
16.0
15.4
—
20
T50 Dual Voltage 600 / 240
240
1ш
2
0.0
6.5
—
15
600
3ш
3
16.0
15.4
—
20
T75
200
1ш
2
20.3
109.8
—
150
208
1ш
2
22.0
113.9
—
150
220
1ш
2
18.5
91.7
92.3
125
230
1ш
2
20.3
—
96.3
125
240
1ш
2
22.0
99.2
—
125
208
3ш
3
22.0
69.2
—
90
220
3ш
3
18.5
56.2
56.8
80
230
3ш
3
20.3
—
59.1
80
240
3ш
3
22.0
60.4
—
80
380
3ш
4
18.5
35.6
—
45
380
3ш
4
18.5
—
36.2
50
400
3ш
4
20.3
—
37.8
50
416
3ш
4
22.0
—
39.1
50